Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1104890
PHOENIX CONTACT 1104890
PHOENIX CONTACTNot available

PSR-M-EF1-SDI8-SDO4-DO4-SC - Extension module

Safe extension module with 8safe inputs and 4safe outputs, 4reset inputs or 4signal outputs, 4 clock outputs, TBUS interface, up to SIL3, Cat.4/PLe, pluggable screw terminal block, TBUS connector included
Product Code: 1104890
Partner cod.: 1104890
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
Product propertiesProduct type: Safety device
Application: Emergency stop
Light grid
Safety door
Safe shutdown
Insulation characteristics
Protection class: III
Times
Response time: see user manual
Restart time: min. 5 s (Boot time)
max. 10 s (Boot time)
Electrical propertiesMaximum power dissipation for nominal condition: 7.48 W (with max. permissible load)
Nominal operating mode: 100% operating factor
Interfaces: DIN rail TBUS for connection to the master module, supplied as standard
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VÂAC
Rated surge voltage/insulation: Basic insulation 4ÂkV between 24ÂV power supply and I/Os to the housing
Supply
Designation: A1/A2
Rated control circuit supply voltage US: 19.2 VÂDC ... 28.8 VÂDC
24 VÂDC -20Â%Â/Â+20Â% (external fuse, typically 4ÂA)
Rated control supply current IS: typ. 45 mA (Outputs inactive)
typ. 68 mA (Outputs active, without load)
Power consumption at US: typ. 1.08 W (Outputs inactive)
Inrush current: < 2.3 A (ΔtÂ=Â1Âms at Us)
Filter time: typ. 5 ms (at A1 in the event of voltage dips at Us)
Protective circuit: Serial protection against polarity reversal
Input dataDigital: IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8
Description of the input: Safety-related digital inputs
IEC 61131-2 TypeÂ2
Number of inputs: 8
Input voltage range "0" signal: 0 VÂDC ... 5 VÂDC
Input voltage range "1" signal: 11 VÂDC ... 28.8 VÂDC
Input current range "0" signal: < 1 mA
Filter time: min. 3 ms ±2Âms (adjustable)
max. 250 ms ±2Âms (adjustable)
Test pulse rate ≥Â2xÂset filter time, min. Test pulse rateÂ=Â10Âms
Cable length: max. 100 m (per input)
Max. permissible overall conductor resistance: max. 1.2 kΩ (Input and reset circuit at US)
Current consumption: typ. 10 mA (typically with US)
max. 12.5 mA (at a control voltage of 28.8ÂVÂDC)
Digital: Reset inputs (FBK)
Description of the input: configurable (as signal output or reset input)
IEC 61131-2 TypeÂ2
Number of inputs: 4
Input voltage range "0" signal: 0 VÂDC ... 5 VÂDC
Input voltage range "1" signal: 11 VÂDC ... 28.8 VÂDC
Input current range "0" signal: < 1 mA
Filter time: 250 ms ±2Âms (Test pulse rateÂ>Â500Âms)
Cable length: max. 100 m (per input)
Max. permissible overall conductor resistance: 1.2 kΩ (Input and reset circuit at US)
Current consumption: typ. 12 mA (typically with US)
max. 14.7 mA (at a control voltage of 28.8ÂVÂDC)
Output dataDigital: O1,ÂO2,ÂO3,ÂO4
Output description: Safety-related digital outputs
PNP, OSSD
IEC 61131-2 typeÂ0.5 (observe limiting continuous current)
Number of outputs: 4
Short-circuit protection: Yes (max. permissible short-circuit current 12ÂA)
Leakage current: max. 250 µA
Cable length: max. 100 m (per output)
Ohmic load: min. 50 Ω (Observe limiting continuous current)
Max. capacitive load: max. 820 nF
Max. inductive load: max. 2.4 mH
Limiting continuous current: 400 mA (per channel)
1.6 A (Total current of all safe digital outputs)
Inrush current: max. 600 mA (ΔtÂ<Â10Âms)
Nominal output voltage: 24 VÂDC (Supply via A1)
Nominal output voltage range: 18.5 VÂDC ... 28.1 VÂDC (USÂ-Â0,7ÂV)
Switching frequency: max. 1/4ÂxÂtCycle [Hz]
Output voltage when switched off: < 0.1 V
Test pulses: < 120 µs (Test pulse width of low test pulses)
≥ 650 ms (Test pulse rate for low test pulse)
< 150 µs (Test pulse width, high test pulse)
≥ 1.5 s (Test pulse rate, high test pulse)
Discharging circuit: Yes, internal
Signal: MO1, MO2, MO3, MO4
Output description: PNP, IEC 61131-2 Typ 0,1
non-safety-related, configurable (as signal output or reset input)
Number of outputs: 4
Output voltage when switched off: max. 0.1 V
Voltage: 24 VÂDC (via A1)
Maximum inrush current: 1.1 A (ΔtÂ=Â3ÂsÂat Us)
Limiting continuous current: 100 mA (per channel)
400 mA (Total current of all digital signal outputs)
Leakage current: max. 100 µA
Switching frequency: max. 1/4ÂxÂtCycle [Hz]
Short-circuit protection: Yes (self-limitation at 1.1ÂA)
Cable length: max. 100 m (per output)
Clock: T1, T2, T3, T4
Output description: PNP, IEC 61131-2 Typ 0,1
Number of outputs: 4
Voltage: 24 VÂDC (via A1)
Output voltage when switched off: max. 0.1 V
Maximum inrush current: 1.1 A (ΔtÂ=Â3ÂsÂat Us)
Limiting continuous current: 100 mA (per channel)
400 mA (Total current of all outputs)
Leakage current: max. 100 µA
Test pulses: ≤ 200 µs (Test pulse duration)
Test pulse rateÂ=Â8ÂxÂtCycle [ms]
Short-circuit protection: Yes (self-limitation at 1.1ÂA)
Cable length: max. 100 m (per output)
Max. capacitive load: max. 470 nF
Max. inductive load: max. 2.4 mH
Discharging circuit: Yes, internal
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque: 0.5 Nm ... 0.6 Nm
SignalingStatus display: 1 x LED (green), 2 x LED (orange)
4 x LED (green, yellow, red)
12 x LED (yellow)
Operating voltage display: 1 x green LED
Error indication: 2ÂxÂLED (red)
DimensionsWidth: 22.61 mm
Height: 112.58 mm
Depth: 113.6 mm
Material specificationsHousing material: Polyamide PA non-reinforced
CharacteristicsSafety data
Stop category: 0
Safety data: ENÂISOÂ13849
Performance level (PL): e (2-channel wiring)
d (1-channel wiring)
Safety data: IEC 61508 - High-demand for 2-channel wiring
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - High-demand for 1-channel wiring
Safety Integrity Level (SIL): 2
Safety data: ENÂIEC 62061
Safety Integrity Level (SIL): 3 (2-channel wiring)
2 (1-channel wiring)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -10°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -20°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 95 % (non-condensing)
Max. permissible relative humidity (operation): 95 % (non-condensing)
Shock: 10g for ΔtÂ=Â16Âms (continuous shock, 1000 shocks in each space direction)
Vibration (operation): 10ÂHzÂ...Â150ÂHz, 2g
ApprovalsCE
Identification: CE-compliant
MountingMounting type: DIN rail mounting
Assembly instructions: Observe derating
Mounting position: vertical or horizontal
Connection method: Screw connection
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00901.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Certification_00224.pdf

Certification_00318.pdf

Data_sheet_00640.pdf

Manual_00057.pdf

Manual_00058.pdf

Manufacturer_declaration_01322.pdf

Manufacturer_declaration_02383.pdf

Manufacturer_declaration_05475.pdf