Industrial Automation
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/11222c50825d6541ae7d9a05b9cf8313/-S204x204-FJPG Width: 284 mm Height: 364 mm Depth: 121 mm |
Material specifications | Material: Polycarbonate PC Polyamide Neoprene Flammability rating according to UL 94: V0 (Housing, a vertically clamped sample is extinguished within 10seconds, no flaming droplets of molten plastic, smoldering for a maximum of 60seconds) V2 (Cable gland; a vertically tensioned sample is extinguished within 30seconds; flaming droplets are permitted) Impact strength: IK10 (in accordance with IEC 62262: Impact energy of 20J, corresponds to 5kg from a height of 40cm) |
Mounting | Mounting type: Wall mounting Mast mounting |
Interfaces | Basic functions: Store-and-forward switch, complies with IEEE802.3 Data: Ethernet / Fast Ethernet / Gigabit Ethernet Transmission speed: 10/100/1000 Mbps Connection method: RJ45 jack No. of channels: 2 (RJ45 ports) Transmission length: 100 m (per segment) Transmission medium: Copper Maximum output power: 165 W (>55°Cderating, see data sheet) 155 W (If switching output is active, >55°Cderating) 90 W (per port POE1/2, >50°Cderating, see data sheet) Data: Ethernet / Fast Ethernet / Gigabit Ethernetâ Transmission speed: 10/100/1000 Mbps Connection method: RJ45 jack No. of channels: 2 (SFP ports) Transmission length: 100 m (per segment) Transmission medium: Copper Data: Configuration interface Connection method: RJ45 jack No. of channels: 1 (RJ45 port) Data: Switching output Connection method: Push-in spring connection No. of channels: 1 (Push-in Technology) Single conductor/terminal point, rigid: 0.2 mm² ... 1.5 mm² Single-wire/terminal point, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 0.75 mm² (Stripping length 8 mm) Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm² (Stripping length 8 mm) Max. AWG conductor cross section, flexible: 16 Min. AWG conductor cross section, flexible: 24 Stripping length: 10 mm Load/output load current output: no inductive load Output nominal voltage: 24 VDC ±10% (Supply for devices within the SmartEthernetBox) Output current: 300 mA (typical) |
Product properties | Product type: Switch Product family: Smart Ethernet Box MTTF: 496 Years (SN29500 standard, temperature25°C, operating cycle21%) 247 Years (SN29500 standard, temperature40°C, operating cycle34.25%) 105 Years (SN29500 standard, temperature40°C, operating cycle100%) Insulation characteristics Protection class: I (Protective grounding of all conductive housing parts) Insulation characteristicsâ Overvoltage category: III (With protection modules plugged in) II (Without protection modules) Pollution degree: 2 Switch functions Diagnostic functions: RMON History LLDP (Link Layer Discovery Protocol) SNMP traps N:1-Portmirroring ACD (Address Conflict Detection) Basic functions: Store-and-forward switch, complies with IEEE802.3 Filter functions: Port prioritization VLAN (up to 32 VLANs) IP parameterization: DHCP client BootP Static IP address MAC address table: 8k Management: Web-based management (HTTP/HTTPS) SNMPv2/v3 Command Line Interface (Telnet, SSH) Redundancy: RSTP (Rapid Spanning Tree Protocol in accordance with IEEE802.1D-2004) Large Tree Support FRD (Fast Ring Detection) Additional functions: Jumbo frames Time synchronization: SNTP (Simple Network Time Protocol) Security functions Basic functions: Store-and-forward switch, complies with IEEE802.3 |
Electrical properties | Rated insulation voltage: 3 kV AC (Input / output, IEC/EN60950-1) Supply Supply voltage range: 100 VAC ... 240 VAC -15%...+10% (Single-phase) |
Connection data | Supply Connection method: Push-in spring connection Conductor cross section flexible, with ferrule without plastic sleeve: 0.2 mm² ... 4 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.2 mm² ... 4 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 1.5 mm² Single conductor/terminal point, rigid: 1 mm² ... 6 mm² Single-wire/terminal point, flexible: 0.2 mm² ... 6 mm² Conductor cross section, flexible [AWG]: 24 ... 10 Stripping length: 10 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 (in accordance with DINEN60529: Complete touch protection, dust cannot enter, spray water from any direction) Impact strength: IK10 (in accordance with IEC 62262: Impact energy of 20J, corresponds to 5kg from a height of 40cm) Ambient temperature (operation): -40°C ... 70°C (>50°Cderating) Ambient temperature (storage/transport): -40°C ... 85°C Altitude: 2000 m Permissible humidity (operation): 10 % ... 95 % (non-condensing) |
Standards and regulations | Other resistance: UV-resistant in accordance with UL746C, f1 listing/rating Outdoor housing, subject to 1,000hour xenon weather testing, 7-day water submergence test Standards/regulations: IEC 62444 IEC 61249-2-21 DINEN45545-2, requirement set R22, hazard level HL3 Standard designation: Strain relief Halogen-free (housing, bromine:<900ppm, chlorine:<900ppm, total halogen content:<1,500ppm) Fire protection |
Approvals | CE Certificate: CE-compliant UKCA Certificate: UKCA-compliant UL, USA/Canada Identification: Listed UL61010-1, 3rd Edition UL61010-2-201, 2nd Edition CAN/CSAC22.2 No.61010-1-12 CSAC22.2 No.61010-2-201:18 Corrosive gas test Identification: ISA-S71.04-1985 G3 Harsh Group A |
EMC data | Noise immunity: EN 61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Conducted noise emission: EN61000-6-3 Class B, domain of use: residential and small commercial Noise emission: EN61000-6-4, ClassB, domain of use: residential and small commercial Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: ± 6 kV Discharge in air: ± 8 kV Indirect discharge: ± 6 kV Comments: Criterion B Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 3 GHz (80%amplitude modulation with 1kHz) Field intensity: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: ± 2.2 kV (1minute) Signal: ± 2.2 kV (1minute) Comments: Criterion B Surge current load (surge) Standards/regulations: EN61000-4-5 Surge current load (surge)â Input: ± 1 kV (AC supply, line to line) ± 2 kV (AC supply, line to ground) Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 0.15 MHz ... 80 MHz (80%amplitude modulation with 1kHz) Comments: Criterion A Voltage: 10 V Emitted interference Standards/regulations: EN61000-6-4 Comments: Class B, domain of use: residential and small commercial Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. |
System properties | Functionality Basic functions: Store-and-forward switch, complies with IEEE802.3 |
ECLASS | ECLASS-11.0: 27180590 ECLASS-12.0: 27180590 ECLASS-13.0: 27180590 |
ETIM | ETIM 9.0: EC000261 |
UNSPSC | UNSPSC 21.0: 31261500 |
Description other products