PHOENIX CONTACT 1114234
PHOENIX CONTACTNot available

SOL-SA-PCU-41XX - Controller

PLCnext Control based on AXC F 2152. Prepared for a customer-specific application with a power generation plant controller. Basis for the feed-in management of power generation systems that feed into medium- and high-voltage grids. Certified in accordance with VDE-AR-N 4110/4120.
Product Code: 1114234
Partner cod.: 1114234
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesGeneral: To operate the product, you will need a product-specific license based on the active power sum of the generating plant. You can purchase the license in the PLCnextStore (for the link, see the “Downloads” tab).
Utilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesType: Axioline
Product type: Controller
Product family: AxiolineF
Insulation characteristics
Protection class: III (IEC 61140, EN61140, VDE0140-1)
System propertiesRetentive data storage: 48 kByte (NVRAM)
IoT capability: PROFICLOUD
IoT platform: PROFICLOUD
Supports cloud computing: yes
IEC 61131 runtime system
Program memory: 8 Mbyte
Data storage system: 16 Mbyte
PROFINET
Device function: PROFINET controller, PROFINET device
Specification: Version 2.3
Update rate: min. 1 ms (4 devices)
min. 16 ms (64 devices)
Conformance Class: A
Number of supported devices: max. 64 (at PROFINET controller)
Supported functions: MRP FSU
MRP
Device ID: 0142hex
Vendor ID: 00B0hex
Functionality
Programming languages supported: Programming in acc. with IEC 61131-3
C++
C#
Java
Manufacturer-specific
System requirements
Engineering tool: PLCnext Engineer
Eclipse
Application interface: OPCUA
Electrical propertiesReal-time clock
Realtime clock: Yes
Description realtime clock: 1.73 s/day = 20ppm at 25°C
InterfacesWeb server: yes
AxiolineF local bus
Number of interfaces: 1
2
Connection method: Bus base module
RJ45 jack
Note on the connection method: Auto negotiation and autocrossing
Transmission speed: 10/100 Mbps (full duplex)
Transmission physics: Ethernet in RJ45 twisted pair
Transmission length: max. 100 m
No. of channels: 2
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/63211ccd321d8a40a4dac68a1b46b1ae/-S204x204-FJPG
Width: 45 mm
Height: 126.93 mm
Depth: 75 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
Material specificationsColor: gray
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C up to 2000m above mean sea level (observe derating)
-25°C ... 55°C up to 3000m above mean sea level (observe derating)
≤ 55°C (with max. 1A on UBus)
> 55°C ... 60°C (only in conjunction with an Axioline F power module AXL F PWR 1H (Item no. 2688297))
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (according to DINEN61131-2)
Permissible humidity (storage/transport): 5 % ... 95 % (according to DINEN61131-2)
Shock (operation): 10g (Bump endurance test according to DIN EN 60068-2-27)
Vibration (operation): 5g
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500m above mean sea level)
EMC dataConformance with EMC directives: Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Fast transients (burst)EN61000-4-4/IEC 61000-4-4 Criterion B, 2kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Conducted interferenceEN61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Noise emission test in accordance with EN61000-6-4/IEC 61000-6-4 ClassA
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27242207
ECLASS-12.0: 27242207
ECLASS-13.0: 27242207
ETIMETIM 9.0: EC000236
UNSPSCUNSPSC 21.0: 32151700