Industrial Automation
Notes | General: To operate the product, you will need a product-specific license based on the active power sum of the generating plant. You can purchase the license in the PLCnextStore (for the link, see the âDownloadsâ tab). Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Type: Axioline Product type: Controller Product family: AxiolineF Insulation characteristics Protection class: III (IEC 61140, EN61140, VDE0140-1) |
System properties | Retentive data storage: 48 kByte (NVRAM) IoT capability: PROFICLOUD IoT platform: PROFICLOUD Supports cloud computing: yes IEC 61131 runtime system Program memory: 8 Mbyte Data storage system: 16 Mbyte PROFINET Device function: PROFINET controller, PROFINET device Specification: Version 2.3 Update rate: min. 1 ms (4 devices) min. 16 ms (64 devices) Conformance Class: A Number of supported devices: max. 64 (at PROFINET controller) Supported functions: MRP FSU MRP Device ID: 0142hex Vendor ID: 00B0hex Functionality Programming languages supported: Programming in acc. with IEC 61131-3 C++ C# Java Manufacturer-specific System requirements Engineering tool: PLCnext Engineer Eclipse Application interface: OPCUA |
Electrical properties | Real-time clock Realtime clock: Yes Description realtime clock: 1.73 s/day = 20ppm at 25°C |
Interfaces | Web server: yes AxiolineF local bus Number of interfaces: 1 2 Connection method: Bus base module RJ45 jack Note on the connection method: Auto negotiation and autocrossing Transmission speed: 10/100 Mbps (full duplex) Transmission physics: Ethernet in RJ45 twisted pair Transmission length: max. 100 m No. of channels: 2 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/63211ccd321d8a40a4dac68a1b46b1ae/-S204x204-FJPG Width: 45 mm Height: 126.93 mm Depth: 75 mm Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715). |
Material specifications | Color: gray |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 60°C up to 2000m above mean sea level (observe derating) -25°C ... 55°C up to 3000m above mean sea level (observe derating) ⤠55°C (with max. 1A on UBus) > 55°C ... 60°C (only in conjunction with an Axioline F power module AXL F PWR 1H (Item no. 2688297)) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (according to DINEN61131-2) Permissible humidity (storage/transport): 5 % ... 95 % (according to DINEN61131-2) Shock (operation): 10g (Bump endurance test according to DIN EN 60068-2-27) Vibration (operation): 5g Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500m above mean sea level) |
EMC data | Conformance with EMC directives: Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Fast transients (burst)EN61000-4-4/IEC 61000-4-4 Criterion B, 2kV Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Conducted interferenceEN61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V Noise emission test in accordance with EN61000-6-4/IEC 61000-6-4 ClassA Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU |
Mounting | Mounting type: DIN rail mounting |