Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1151412
PHOENIX CONTACT 1151412
PHOENIX CONTACTNot available

AXC F 1152 - Controller

PLCnextControl for the direct control of Axioline F I/Os. With two Ethernet interfaces. Complete with connector and bus base module.
Product Code: 1151412
Partner cod.: 1151412
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesType: modular
Product type: Controller
Product family: PLCnext Control
Insulation characteristics
Protection class: III (IEC 61140, EN61140, VDE0140-1)
Overvoltage category: II
Display
Diagnostics display: No
System propertiesProcessor: Arm® Cortex®-A9 1x 800 MHz
Flash memory: 512 Mbyte (internal flash memory)
SD card from PhoenixContact (for external flash memory, see accessories)
Retentive data storage: 48 kByte (NVRAM)
RAM: 512 Mbyte DDR3 SDRAM
IoT capability: PROFICLOUD
IoT platform: PROFICLOUD
Supports cloud computing: yes
IEC 61131 runtime system
Program memory: 8 Mbyte
Data storage system: 12 Mbyte
Axioline
Amount of process data: max. 1482 Byte (per station (total input and output data))
max. 1024 Byte (AxiolineF local bus (input))
max. 1024 Byte (AxiolineF local bus (output))
Number of supported devices: max. 63 (per station)
Number of local bus devices that can be connected: max. 63 (observe current consumption)
PROFINET
Device function: PROFINET controller, PROFINET device
Specification: Version 2.3
Update rate: min. 1 ms (4 devices)
min. 4 ms (16 devices)
Conformance Class: A
Number of supported devices: max. 16 (at PROFINET controller)
Supported functions: MRP FSU PROFINET controller
MRP PROFINET device
Device ID: 0169hex
Vendor ID: 00B0hex
Function
Diagnostics display: No
Controller redundancy: No
Safety function: No
Functionality
Programming languages supported: Symbolic flowchart (SFC)
Ladder diagram (LD)
Function block diagram (FBD)
Structured text (ST)
C++
C#
Java
Python
Simulink
System requirements
Engineering tool: PLCnext Engineer
Eclipse
Visual Studio
MATLAB® Simulink®
Application interface: OPCUA
Electrical propertiesReal-time clock
Realtime clock: Yes
Description realtime clock: 1.73 s/day = 20ppm at 25°C
Potentials: Communications power U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple (±5%))
Current draw: max. 442 mA (with 1A at UBus for the I/Os and UL = 24 V)
Power consumption: max. 10.6 W (with 1A at UBus for the I/Os and UL = 24 V)
Protective circuit: Surge protection; electronic
Reverse polarity protection; electronic
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Power supply unit: 1 A
Connection dataAxiolineF connector
Connection method: Push-in connection
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
InterfacesSupported protocols: HTTP
HTTPS
PROFINET
Modbus/TCP (via corresponding library)
Modbus/RTU (via corresponding library)
Ethernet/IP (Adapter)
CANopen® (via corresponding library)
DALI (via corresponding library)
DALI2 (via corresponding app)
HART (via corresponding app)
IO-Link (via corresponding app)
MQTT (via corresponding app)
OPCUAServer
OPCUAClient (via corresponding app)
DHCP (via corresponding app)
SFTP
SMTP (via corresponding app)
SNTP (via corresponding app)
SNMP (via corresponding app)
DNS (via corresponding app)
DNP3 (via corresponding app)
IEC 60870-5-1 (via corresponding library)
IEC 60870-5-104 (via corresponding library)
IPsec
syslog
Web server: yes
AxiolineF local bus
Number of interfaces: 1
Connection method: Bus base module
Transmission speed: 100 Mbps
Ethernet
Bus system: RJ45
Number of interfaces: 2 (Switched internally)
Connection method: RJ45 jack
Note on the connection method: Auto negotiation and autocrossing
Transmission speed: 10/100 Mbps (full duplex)
Transmission physics: Ethernet in RJ45 twisted pair
Transmission length: max. 100 m
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/63211ccd321d8a40a4dac68a1b46b1ae/-S204x204-FJPG
Width: 45 mm
Height: 126.93 mm
Depth: 75 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C up to 2000m above mean sea level (observe derating)
-25°C ... 55°C up to 3000m above mean sea level (observe derating)
55°C (with max. 1A on UBus)
55°C ... 60°C (only in conjunction with an Axioline F power module AXL F PWR 1H (Item no. 2688297))
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (according to DINEN61131-2)
Permissible humidity (storage/transport): 5 % ... 95 % (according to DINEN61131-2)
Shock (operation): 30g (in accordance with EN60068-2-27/IEC 60068-2-27)
Vibration (operation): 5g (in accordance with EN60068-2-6/IEC 60068-2-6)
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500m above mean sea level)
ApprovalsUL, USA/Canada
Identification: cULus
Certificate: E238705
Industrial Cyber Security
Identification: IndustrialITSecurity, IACSComponent
Certificate: IITS20294290027
Note: Configuration: SecurityProfileactive
EMC dataConformance with EMC directives: Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Fast transients (burst)EN61000-4-4/IEC 61000-4-4 Criterion B, 2kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN61000-4-5/IEC 61000-4-5 CriterionB; DC supply lines: ±0.5kV/±1.0kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1.0kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Conducted interferenceEN61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Noise emission test in accordance with EN61000-6-4/IEC 61000-6-4
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
MountingMounting type: DIN rail mounting
Connection method: Push-in connection
Technical Specs
ECLASSECLASS-11.0: 27242207
ECLASS-12.0: 27242207
ECLASS-13.0: 27242207
ETIMETIM 9.0: EC000236
UNSPSCUNSPSC 21.0: 32151700
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00110.pdf

Application_note_00034.pdf

Approvals_01756.pdf

Approvals_01792.pdf

Approvals_01935.pdf

Manual_00006.pdf

Manual_00040.pdf

Manual_00007.pdf

Manufacturer_declaration_01271.pdf

Manufacturer_declaration_01898.pdf

Manufacturer_declaration_06600.pdf

Package_slip_00625.pdf

Product_information_00033.pdf

Product_information_00088.pdf

Technical_drawing_09435.pdf