Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1190012
PHOENIX CONTACT 1190012
PHOENIX CONTACTAvailable

AXL SE SSDI8/3 - Safety module

Axioline SmartElements, Digital input module, Functional safety, SafetyBridge technology, Safe digital inputs: 4 (2-channel assignment), 8 (1-channel assignment), 24 VDC, connection technology: 3-conductor, degree of protection: IP20
Product Code: 1190012
Partner cod.: 1190012
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22530/full/b250?format=jpg
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
InterfacesSmartÂElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartÂElement.
System propertiesModule
Input address area: 6 Byte
Output address area: 5 Byte
Input dataDigital
Input name: Safe digital inputs
Description of the input: EN 61131-2, type 3
Number of inputs: 4 (2-channel assignment)
8 (1-channel assignment)
Cable length: max. 200 m (200 m from the clock output to the safe input (total based on forward and return path))
Connection method: Push-in connection
Connection technology: 3-conductor
Input voltage range "0" signal: -3 VÂDC ... 5 VÂDC
Input voltage range "1" signal: 11 VÂDC ... 30 VÂDC
Nominal input voltage UIN: 24 VÂDC
Nominal input current at UIN: typ. 2.7 mA
Input filter time: 1.5 ms
3 ms (Default)
5 ms
15 ms
Protective circuit: Polarity reversal protection of the inputs; Diode
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartÂElements
Mounting position: any
Application: Functional safety
SafetyBridge technology
Operating mode: SafetyBridge
Insulation characteristics
Overvoltage category: II (IEC 60664-1)
Pollution degree: 2 (ENÂ60664-1)
Electrical propertiesPotentials
Protection: external fusing via the system in which the SmartÂElement is used
Protective circuit: Surge protection of the supply voltage; electronic (35 V, 0.5 s)
Polarity reversal protection of the supply voltage; via the system in which the SmartÂElement is used
Potentials: AxiolineÂF local bus supply (U
Supply voltage: 5 VÂDC (via bus base module)
Current draw: max. 140 mA (at UBus 5ÂVÂDC)
typ. 101 mA (at UBus 5ÂVÂDC)
Potentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VÂDC (using card edge connectors)
Supply voltage range: 19.2 VÂDC ... 30 VÂDC (including all tolerances, including ripple)
Current draw: max. 12 mA (Power supply from Up with 30ÂVÂDC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
typ. 9 mA (Power supply from Up with 24ÂVÂDC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
Current consumption: min. 8 mA (Power supply from Up with 19.2ÂVÂDC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
Power consumption: max. 360 mW
min. 154 mW
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Degree of protection at installation location: min. IP54
Air pressure (operation): 70 kPa ... 108 kPa
Air pressure (storage/transport): 66 kPa ... 108 kPa
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
Air clearances and creepage distances
Air clearances and creepage distances: IEC 60664-1
MountingMounting type: Smart Element slot
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00523.pdf

Approvals_01798.pdf

Approvals_01799.pdf

Certification_00369.pdf

Manual_00045.pdf

Manual_00087.pdf

Manufacturer_declaration_01310.pdf

Manufacturer_declaration_02313.pdf

Manufacturer_declaration_06732.pdf

Package_slip_00780.pdf

Product_information_00033.pdf

Product_information_00999.pdf

Technical_drawing_09956.pdf