Industrial Automation
Product properties | Product type: Data cable preassembled Sensor type: Ethernet Number of positions: 8 Shielded: yes Cable outlet: straight Insulation characteristics Overvoltage category: I Degree of pollution: 2 |
Electrical properties | Rated voltage (III/2): 72 V Transmission medium: Copper Transmission characteristics (category): CAT5 Power transmission: PoE++ |
Mechanical properties | Mechanical data Insertion force per signal contact: 30.00 N Extraction force per signal contact: 50 N |
Material specifications | Flammability rating according to UL 94: V0 Contact material: Brass Contact surface material: Au Contact carrier material: PC Outer sheath, material: LSZH |
Dimensions | Width: 11.6 mm Height: 14.8 mm Length: 40 mm |
Connection data | Connection technology Connection method: Pierce connection Conductor connection Connection method: Pierce connection |
Connector | Connection 1 Type: Plug straight RJ45 Shielded: yes Handle color: gray Insertion/withdrawal cycles: ⥠750 750 Degree of protection: IP20 Ambient temperature (operation): -20°C ... 80°C Number of positions: 8 Connection 2 Type: Plug straight RJ45 Shielded: yes Handle color: gray Insertion/withdrawal cycles: ⥠750 Ambient temperature (operation): -20°C ... 80°C Number of positions: 8 Degree of protection: IP20 |
Cable/line | Cable length: 5.00 m Ethernet, Type B, 8-pos., CAT5, LSZH[BC5] Shielded: yes Cable type: Ethernet, Type B, 8-pos., CAT5, LSZH Cable type (abbreviation): BC5 Cable structure: 2x2xAWG26/7, S/UTP External cable diameter: 5.7 mm ±0.3mm Outer sheath, material: LSZH External sheath, color: gray Thickness, outer sheath: approx. 0.7 mm Conductor material: Bare Cu litz wires Conductor structure signal line: 7x 0.16 mm AWG signal line: 26 Material wire insulation: PE Single wire, number of litz wires: 8 Wire diameter incl. insulation: 0.85 mm Single wire, cross section [AWG]: 26 Shielding: S/UTP Optical shield covering: 70 % Cable insulation resistance: ⥠5000 Mé*km Wave impedance: 100 é Loop resistance: ⤠148.00 é/km Minimum bending radius, fixed installation: 8 x D Damping: 3.2 dB (with 1 MHz) 6.01 dB (at 4 ÃHz) 9.49 dB (at 10 MHz) 12.07 dB (at 16 MHz) 13.54 dB (at 20ÃHz) 17.11 dB (at 31.25ÃHz) 24.76 dB (at 62.5ÃHz) 31.99 dB (at 100 MHz) Near end crosstalk attenuation (NEXT): 65.3 dB (with 1 MHz) 56.3 dB (at 4 ÃHz) 50.3 dB (at 10 MHz) 47.2 dB (at 16 MHz) 45.8 dB (at 20ÃHz) 42.9 dB (at 31.25ÃHz) 38.4 dB (at 62.5ÃHz) 35.3 dB (at 100 MHz) Power-summated near end crosstalk attenuation (PSNEXT): 62.3 dB (with 1 MHz) 53.3 dB (at 4 ÃHz) 48.8 dB (at 8ÃHz) 47.3 dB (at 10 MHz) 44.2 dB (at 16 MHz) 42.8 dB (at 20ÃHz) 41.3 dB (at 25MHz) 39.9 dB (at 31.25ÃHz) 35.4 dB (at 62.5ÃHz) 32.3 dB (at 100 MHz) Return attenuation (RL): 20 dB (with 1 MHz) 23 dB (at 4 ÃHz) 24.5 dB (at 8ÃHz) 25 dB (at 10 MHz) 25 dB (at 16 MHz) 25 dB (at 20ÃHz) 24.2 dB (at 25MHz) 23.3 dB (at 31.25ÃHz) 20.7 dB (at 62.5ÃHz) 19 dB (at 100 MHz) Halogen-free: complying with IEC 60754-1/2 Flame resistance: IEC 60332-1-2/IEC 60332-3-24/CM Ambient temperature (operation): -20°C ... 80°C (Cable, flexible installation) -20°C ... 80°C (cable, fixed installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -20°C ... 80°C Ambient temperature (storage/transport): 0°C ... 40°C |
Standards and regulations | Flame resistance: IEC 60332-1-2 |