PHOENIX CONTACT 1268817
PHOENIX CONTACTNot available

F-MS-T1/T2 50 P - Type 1/2 surge protection plug

T1/T2 lightning/surgeprotectionplug, with N-PE total current spark gap for VAL-MS-T1/T2PTbase element.
Product Code: 1268817
Partner cod.: 1268817
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesIEC test classification: I / II
T1 / T2
EN type: T1 / T2
IEC power supply system: TN-S
TT
Type: DIN rail module, two-section, divisible
Product type: Replacement plug
Product family: VALVETRAB MS
Number of positions: 1
Surge protection fault message: optical
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Connection dataConnection method: pluggable
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/244085b8304de74e95f3135ca62ba23a/-S204x204-FJPG
Width: 17.5 mm
Height: 47.2 mm
Depth: 63.9 mm
Horizontal pitch: 1 Div.
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA 6.6/PBT
Material group: I
Housing material: PA 6.6
PBT
Protective circuitMode of protection: N-PE
Direction of action: N-PE
Nominal voltage UN: 240/415VAC (TN-S)
240/415VAC (TT)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 264 VAC
Residual current IPE: ≤ 5 µA
Standby power consumption PC: ≤ 1.3 mVA
Nominal discharge current In (8/20) µs: 50 kA
Maximum discharge current Imax (8/20) µs: 50 kA
Impulse discharge current (10/350)µs, charge: 25 As
Impulse discharge current (10/350)µs, specific energy: 625 kJ/Ω
Impulse discharge current (10/350)µs, peak value limp: 50 kA
Follow current interrupt rating Ifi: 100 A (264 V AC)
Voltage protection level Up: ≤ 1.7 kV
Residual voltage Ures: ≤ 0.6 kV (at In)
≤ 0.5 kV (at 10 kA)
≤ 0.5 kV (at 5 kA)
≤ 0.4 kV (at 3kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs: ≤ 1.7 kV
TOV behavior at UT: 1200 VAC (200ms / withstand mode)
Response time tA: ≤ 100 ns
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 85°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Standards and regulationsStandards/specifications: IEC 61643-11
EN61643-11
Note: 2011
2012
MountingMounting type: on base element
Technical Specs
ECLASSECLASS-11.0: 27130890
ECLASS-13.0: 27171292
ETIMETIM 8.0: EC002496
UNSPSCUNSPSC 21.0: 39121600