Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1393553
PHOENIX CONTACT 1393553
PHOENIX CONTACTNot available

CAPAROC PM EIP - Power module

Power module with EtherNet/IPâ„¢ interface for supplying the CAPAROC circuit breaker system with 12 V DC or 24 V DC. Additional system interface for communication with the power supply. For DIN rail installation via the CAPAROC current rails.
Product Code: 1393553
Partner cod.: 1393553
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Description
Tecnichal data
NotesGeneral
Note: LABS release âۉ€œ in accordance with test specification VW PV 3.10.7:2005-0
When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules.
Product propertiesProduct type: Device circuit breakers
Product family: CAPAROC
Number of slots: 4
Data management status
Article revision: 01
Insulation characteristics
Protection class: III
Pollution degree: 2
Electrical propertiesGeneral
Operating voltage: 10 V DC ... 30 V DC
Rated voltage: 12 V DC
24 V DC
Rated current IN: 45 A DC (Total current input)
Rated surge voltage: 0.5 kV
Tripping method: E (electronic)
Feedback resistance: max. 35 V DC
Dielectric strength: 35 V DC (Load circuit)
Efficiency: > 99 %
Closed circuit current I0: typ. 46 mA (no load at 24 V)
Power dissipation: typ. 1.1 W (no load at 24 V)
< 4.5 W (at 40 A)
Temperature derating: 45 A (Total current at 60 °C)
20 A (Total current at 65 °C)
45 A (Total current at 35 °C, in accordance with UL)
40 A (Total current at 40 °C, in accordance with UL)
15 A (Total current at 50 °C, in accordance with UL)
MTBF (IEC 61709, SN 29500): 7242508.37 h (at 25 °C with 21 % load)
3958056.77 h (at 40 °C with 34.25% load)
764697.81 h (at 60 °C with 100% load)
Voltage drop: 0.082 V (at 40 A)
Load circuit
Undervoltage switch-off: ≤ 9.2 V DC (active)
≥ 10.2 V DC (inactive)
Overvoltage switch-off: ≥ 30.5 V DC (active)
≤ 29.5 V DC (inactive)
Connection dataMain circuit IN+
Connection method: Push-in connection
Stripping length: 18 mm
Conductor cross section AWG: 20 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.5 mm² ... 16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.5 mm² ... 16 mm²
Main circuit IN-
Connection method: Push-in connection
Stripping length: 18 mm
Conductor cross section AWG: 20 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.5 mm² ... 16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.5 mm² ... 16 mm²
System communication
Connection method: Push-in connection
Stripping length: 8 mm
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.2 mm² ... 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.2 mm² ... 1.5 mm²
InterfacesEtherNet/IPâ„¢
Maximum system extension: ≤ 16 (CAPAROC modules alignable)
Interface type: Ethernet
Number: 2
Transmission speed: 10 Mbps 100 Mbps
Transmission physics: Ethernet in RJ45 twisted pair
Protocols supported: EtherNet/IPâ„¢
SignalingConnection X1 LED green: lit (connect)
Connection X1 LED yellow: lit (traffic)
Connection X2 LED green: lit (connect)
Connection X2 LED yellow: lit (traffic)
Power (PWR) LED green: lit (Supply voltage within the operating voltage range)
3x flashing (Global programming lock deactivated)
Power (PWR) LED red: lit (Supply voltage outside the operating voltage range)
5x flashing (Factory reset command accepted)
Power (PWR) LED yellow: lit (PWR button pressed)
3x flashing (Global programming lock activated)
NET LED off: off (No voltage present at the device or no IP address configured)
NET LED green: lit (Communication with the controller present)
flashing (IP address available, no communication with the controller)
NET LED red: lit (Address Conflict Detection (ACD): âہ“Duplicate IP.” Device has detected that its IP address is already in use in the network.)
NET LED red-green: flashing (Device initialization self-test)
MOD LED off: off (No supply voltage)
MOD LED green: lit (Normal operation)
flashing (The device is not yet configured)
MOD LED red-green: flashing (Device initialization self-test)
MOD LED red: lit (Error (EtherNet/IPâ„¢: âہ“Major unrecoverable fault”), e.g., program crash in the controller)
flashing (Error (EtherNet/IPâ„¢: âہ“Major recoverable fault”), e.g., inconsistent or incorrect parameterization)
Ready (RDY) LED yellow-green: flashing (Firmware installation running)
Ready (RDY) LED yellow: lit (Firmware installation failed, perform manual voltage reset)
Ready (RDY) LED green: lit (Firmware started successfully)
DimensionsDimensional drawing: https://caas.phoenixcontact.com/caas/v1/stable/media/49228/full/b1500?format=jpg
Width: 24.8 mm
Height: 132.4 mm
Depth: 111.3 mm (incl. DIN rail 7.5 mm)
Material specificationsColor: light gray (RAL 7035)
Material: PA 6
PC
Flammability rating according to UL 94: V-0
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -30 °C ... 65 °C
Ambient temperature (storage/transport): -40 °C ... 70 °C
Altitude: ≤ 4000 m (amsl)
Humidity test: 96 h, 95 % RH, 40 °C
Shock (operation): 30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27)
25g (6 ms duration, half-sine shock pulse in accordance with IEC 60068-2-27, continuous shock)
Vibration (operation): 5g (10 ... 150 Hz / 10 cycles / axis / X, Y, Z)
ApprovalsUL approval
Identification: UL/C-UL Listed UL 508
UL 121201 Class I, Division 2, Groups A, B, C, D, T4A
Standards and regulationsStandards/specifications: EN 61000-6-2
EN 61000-6-4
EN 61000-6-8
EN 60068-2-78
EN 50178
EN 60068-2-6
EN 60068-2-27
Note: EMC âۉ€œ Immunity for industrial areas
EMC interference emission for professional devices that are used in business and commercial areas as well as in small businesses
Environmental influences âۉ€œ Moisture and heat, constant
Equipping power installations with electronic equipment
Environmental influences âۉ€œ Vibrations (sinusoidal)
Environmental influences âۉ€œ Shocks
MountingMounting type: pluggable onto CAPAROC CR… current rail
Description
CAPAROC PM EIP Modulo alimentazione Eth-IP