Industrial Automation
Notes | Safety note Safety note: WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. ⢠WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. ⢠WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. ⢠The products are suitable for applications in plant, controller, and electrical device engineering. ⢠When operating the connectors in outdoor applications, they must be separately protected against environmental influences. ⢠Assembled products may not be manipulated or improperly opened. ⢠Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). ⢠When using the product in direct connection with third-party manufacturers, the user is responsible. ⢠For operating voltages > 50V AC, conductive connector housings must be grounded ⢠Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. ⢠Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product ⢠Only use tools recommended by PhoenixContact ⢠Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products ⢠Ensure that the protective or functional ground has been properly connected. ⢠VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector ⢠The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). |
Product properties | Product type: Data cable preassembled Sensor type: PROFINET Number of positions: 4 No. of cable outlets: 1 Shielded: yes Coding: D Insulation characteristics Overvoltage category: II Degree of pollution: 3 |
Interfaces | Bus system: PROFINET Signal type/category: PROFINET CAT5 (IEC 11801:2002), 100 Mbps |
Electrical properties | Rated surge voltage: 2.5 kV Nominal voltage UN: 250 V Nominal current IN: 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) Transmission medium: Copper Transmission characteristics (category): CAT5 (IEC 11801:2002) Wave impedance: 100 é |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠100 |
Material specifications | Flammability rating according to UL 94: V0 Seal material: FKM Contact surface material: Ni/Au Contact carrier material: PA 6.6 Material for screw connection: Brass, nickel-plated Outer sheath, material: PE-X Conductor material: silver-plated Cu litz wires |
Connector | Connection 1 Head design: Socket Head cable outlet: straight Head thread type: M12 Head locking type: SPEEDCON Coding: D Connection 2 Head design: free cable end |
Cable/line | Cable length: 5 m PROFINET RADOX Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/35eeeb11fbacdc4187dc972d16fa1966/-S204x204-FJPG Cable weight: 70 kg/km Number of positions: 4 Shielded: yes Cable type: PROFINET RADOX® railway application CAT5[937] Conductor structure: 1x4xAWG22/7, SF/TQ Signal speed: 75 c Conductor structure signal line: 7x 0.25 mm AWG signal line: 22 Conductor cross section: 4x 0.34 mm² Wire diameter incl. insulation: approx. 1.5 mm External cable diameter: 6.6 mm ±0.4mm Outer sheath, material: PE-X External sheath, color: black RAL9005 Conductor material: silver-plated Cu litz wires Material wire insulation: Foamed PE Single wire, color: white-blue, orange-yellow Thickness, outer sheath: approx. 1 mm Overall twist: Star quad Max. conductor resistance: ⤠54.4 é/km Coupling resistance: 200.00 mé/m (f ⤠30 MHz) Wave impedance: 100 é ±5é (f = 100 MHz) Working capacitance: ⤠65 pF (Line-line) ⤠100 pF (Line-shield) Nominal voltage, cable: 300 VAC Test voltage: 2000 VAC (50 Hz, 5 minutes) Minimum bending radius, fixed installation: 6 x D Near end crosstalk attenuation (NEXT): 73 dB (with 1 MHz) 70 dB (at 4 ÃHz) 65 dB (at 10 MHz) 57 dB (at 31.5ÃHz) 52 dB (at 62.5ÃHz) 48 dB (at 100 MHz) Return attenuation (RL): 25 dB (at 4 ÃHz) 30 dB (at 10 MHz) 30 dB (at 31.5ÃHz) 30 dB (at 62.5ÃHz) 28 dB (at 100 MHz) Remote crosstalk attenuation (FEXT): 78 dB (with 1 MHz) 77 dB (at 4 ÃHz) 70 dB (at 10 MHz) 65 dB (at 31.5ÃHz) 56 dB (at 62.5ÃHz) 48 dB (at 100 MHz) Shield attenuation: 2 dB (with 1 MHz) 4.4 dB (at 4 ÃHz) 7.4 dB (at 10 MHz) 14 dB (at 31.5ÃHz) 20 dB (at 62.5ÃHz) 26 dB (at 100 MHz) 40 dB (30 MHz ⤠f ⤠100 MHz) Halogen-free: in accordance with EN 50267-2-1 Flame resistance: EN60332-1-2 EN50266 EN60332-3-25 NFC32-070, 2.1 NFC32-070, 2.2 UL1685, 12 (FT4) in accordance with ISO6722-1 5.22 (UN ECE-R 118.01) Fume corrosiveness: EN50267-2-2 Fume toxicity: BS6853 B.1 EN50305, 9.2 Concentration of fumes: BS 6853 D.8.7 EN 61034-2 UL 1685, 12 (FT4) Resistance to oil: according to IRM 902, 72 h at 100°C Fire protection in rail vehicles: BS6853 (Category Ia, Ib, II) GM/RT2130 (Category Ia, Ib, II) EN45545 (Risk level HL1 - HL3) DIN5510 (Fire protection level 1, 2, 3, 4) NFF16-101 (Category A1, A2, B) NFF16-101 (Class C/F0) NFPA130 UNICEI11170 (Risk level LR1 - LR4) Other resistance: Resistance to fuels according to IRM 903, 168 h at 70°C Ambient temperature (operation): -50°C ... 90°C (cable, fixed installation) -40°C ... 90°C (Cable, flexible installation) Ambient temperature (installation): -25°C ... 90°C |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65/IP67 Ambient temperature (operation): -25°C ... 85°C (Plug / socket) -40°C ... 85°C (without mechanical actuation) |
Standards and regulations | M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-101 |
ECLASS | ECLASS-11.0: 27060308 ECLASS-12.0: 27060308 ECLASS-13.0: 27060308 |
ETIM | ETIM 9.0: EC002599 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products