Industrial Automation
Notes | General: The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Safety note Safety note: WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. ⢠WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. ⢠WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. ⢠The products are suitable for applications in plant, controller, and electrical device engineering. ⢠When operating the connectors in outdoor applications, they must be separately protected against environmental influences. ⢠Assembled products may not be manipulated or improperly opened. ⢠Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). ⢠When using the product in direct connection with third-party manufacturers, the user is responsible. ⢠For operating voltages > 50V AC, conductive connector housings must be grounded ⢠Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. ⢠Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product ⢠Only use tools recommended by PhoenixContact ⢠Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products ⢠Ensure that the protective or functional ground has been properly connected. ⢠VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector ⢠The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). |
Product properties | Product type: Data cable preassembled Sensor type: Ethernet Number of positions: 8 No. of cable outlets: 1 Shielded: yes Coding: X Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Interfaces | Signal type/category: Ethernet CAT6A, 10 Gbps |
Electrical properties | Rated surge voltage: 0.8 kV Contact resistance: ⤠3 mé Insulation resistance: ⥠100 Mé Nominal voltage UN: 50 VAC 60 VDC Nominal current IN: 0.5 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) Transmission medium: Copper Transmission characteristics (category): CAT6A |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠100 |
Material specifications | Flammability rating according to UL 94: V0 Seal material: FKM Contact material: CuZn Contact surface material: Au Contact carrier material: PPA Material for screw connection: Zinc die-cast, nickel-plated Outer sheath, material: PUR |
Connection data | Connection technology Connection method: Bus line Conductor connection Contact connection type: Crimp contacts Connection method: Bus line Tightening torque: 2 Nm ... 3 Nm (Installation-side) |
Connector | Connection 1 Head design: Socket Head cable outlet: straight Head thread type: M12 Head locking type: SPEEDCON Coding: X Connection 2 Head design: free cable end |
Cable/line | Cable length: 10 m Ethernet 10 Gbit[94F] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/0314c1656ba7d3438a5ae0749b98c42e/-S204x204-FJPG Cable weight: 42 kg/km UL AWM Style: 20963 (80°C/30 V) Number of positions: 8 Shielded: yes Cable type: Ethernet 10 Gbit[94F] Conductor structure: 4x2xAWG26/7; S/FTP Signal runtime: 5.13 ns/m Conductor structure signal line: 7x 0.16 mm AWG signal line: 26 Conductor cross section: 4x 2x 0.14 mm² Wire diameter incl. insulation: 1.04 mm External cable diameter: 6.4 mm ±0.2mm Outer sheath, material: PUR External sheath, color: water blue RAL5021 Conductor material: Bare Cu litz wires Material wire insulation: Foamed PE Single wire, color: white/blue-blue, white/orange-orange, white/green-green, white/brown-brown Thickness, outer sheath: 0.65 mm Twisted pairs: 2 cores to the pair Type of pair shielding: Aluminum-lined foil Overall twist: 4 pairs for core Optical shield covering: 70 % Insulation resistance: ⥠500 Mé*km Loop resistance: ⤠290.00 é/km Wave impedance: 100 é ±5é (at 100 MHz) Cable capacity: 47 nF/km Nominal voltage, cable: ⤠100 V Test voltage Core/Core: 700 V (50Hz, 1min.) Test voltage Core/Shield: 700 V (50Hz, 1min.) Minimum bending radius, fixed installation: 4 x D Minimum bending radius, flexible installation: 8 x D Smallest bending radius, fixed installation: 26 mm Smallest bending radius, movable installation: 52 mm Tensile strength: ⤠100 N Near end crosstalk attenuation (NEXT): 75.3 dB (with 1 MHz) 66.3 dB (at 4 ÃHz) 61.8 dB (at 8ÃHz) 60.3 dB (at 10 MHz) 57.2 dB (at 16 MHz) 55.8 dB (at 20ÃHz) 54.3 dB (at 25MHz) 52.8 dB (at 31.25ÃHz) 48.4 dB (at 62.5ÃHz) 45.3 dB (at 100 MHz) 40.8 dB (at 200 MHz) 39.3 dB (at 250MHz) 38.1 dB (at 300MHz) 38.1 dB (at 400MHz) 38.1 dB (at 500MHz) Power-summated near end crosstalk attenuation (PSNEXT): 72.3 dB (with 1 MHz) 63.3 dB (at 4 ÃHz) 58.8 dB (at 8ÃHz) 57.3 dB (at 10 MHz) 54.2 dB (at 16 MHz) 52.8 dB (at 20ÃHz) 51.3 dB (at 25MHz) 49.9 dB (at 31.25ÃHz) 45.4 dB (at 62.5ÃHz) 42.3 dB (at 100 MHz) 37.8 dB (at 200 MHz) 36.3 dB (at 250MHz) 35.1 dB (at 300MHz) 33.3 dB (at 400MHz) 31.8 dB (at 500MHz) Return attenuation (RL): 20 dB (with 1 MHz) 23 dB (at 4 ÃHz) 24.5 dB (at 8ÃHz) 25 dB (at 10 MHz) 25 dB (at 16 MHz) 25 dB (at 20ÃHz) 24.2 dB (at 25MHz) 23.3 dB (at 31.25ÃHz) 20.7 dB (at 62.5ÃHz) 19 dB (at 100 MHz) 16.4 dB (at 200 MHz) 15.6 dB (at 250MHz) 15.6 dB (at 300MHz) 15.6 dB (at 400MHz) 15.6 dB (at 500MHz) Shield attenuation: 3.1 dB (with 1 MHz) 5.7 dB (at 4 ÃHz) 8 dB (at 8ÃHz) 8.9 dB (at 10 MHz) 11.2 dB (at 16 MHz) 12.6 dB (at 20ÃHz) 14.1 dB (at 25MHz) 15.8 dB (at 31.25ÃHz) 22.5 dB (at 62.5ÃHz) 28.7 dB (at 100 MHz) 41.4 dB (at 200 MHz) 46.6 dB (at 250MHz) 51.4 dB (at 300MHz) 60.1 dB (at 400MHz) 67.9 dB (at 500MHz) ⥠80 dB (at 30 ... 100 MHz) Halogen-free: according to IEC 60754-1 Flame resistance: according to IEC 60332-1-2 Resistance to oil: in accordance with DINEN60811-2-1 Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation) -20°C ... 80°C (Cable, flexible installation) Ambient temperature (installation): -20°C ... 80°C |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP67 IP65 IP65/IP67 Ambient temperature (operation): -25°C ... 85°C (Plug / socket) -40°C ... 85°C (without mechanical actuation) |
Standards and regulations | M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-109 |
ECLASS | ECLASS-11.0: 27281101 ECLASS-12.0: 27281101 ECLASS-13.0: 27281101 |
ETIM | ETIM 8.0: EC000761 |
UNSPSC | UNSPSC 21.0: 39131500 |