Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1415595
PHOENIX CONTACTNot available

NBC-MSX/ 2,0-94S/MSX SCO RAIL - Network cable

Network cable, Ethernet CAT6A (10 Gbps), 8-position halogen-free, shielded, Plug straight M12, coding: X SPEEDCON / IP65, on Plug straight M12, coding: X SPEEDCON / IP65, cable length: 2 m
Product Code: 1415595
Partner cod.: 1415595
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Data cable preassembled
Sensor type: Ethernet
Number of positions: 8
Application: Railway applications
No. of cable outlets: 1
Shielded: yes
Coding: X
InterfacesBus system: Ethernet
Signal type/category: Ethernet CAT6A, 10 Gbps
SignalingStatus display: No
Status display present: No
Electrical propertiesNominal voltage UN: 48 VAC
60 VDC
Nominal current IN: 0.5 A
Transmission medium: Copper
Transmission characteristics (category): CAT6A
ConnectorConnection 1
Type: Plug straight M12 SPEEDCON / IP65
Number of positions: 8
Coding type: X (Data)
Handle color: black
Material: CuZn (Contact)
Ni/Au (Contact surface)
TPU (Contact carriers)
PA 6.6 (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Standards/regulations: PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3)
Insertion/withdrawal cycles: ≥ 100
100
Contact resistance: ≤ 5 mΩ
Insulation resistance: ≥ 100 MΩ
Tightening torque: 0.4 Nm
Degree of protection: IP65
IP67
Ambient temperature (operation): -25°C ... 90°C
Locking type: SPEEDCON
Connection 2
Type: Plug straight M12 SPEEDCON / IP65
Number of positions: 8
Coding type: X (Data)
Handle color: black
Material: CuZn (Contact)
Ni/Au (Contact surface)
TPU (Contact carriers)
PA 6.6 (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Standards/regulations: PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3)
Insertion/withdrawal cycles: ≥ 100
Contact resistance: ≤ 5 mΩ
Insulation resistance: ≥ 100 MΩ
Tightening torque: 0.4 Nm
Ambient temperature (operation): -25°C ... 90°C
Degree of protection: IP65
Locking type: SPEEDCON
Cable/lineCable length: 2 m
Ethernet BETAtrans
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/1f08ac23481cba498cd37c88ad48a160/-S204x204-FJPG
Cable weight: 59 kg/km
Copper weight: 28 kg/km
Number of positions: 8
Shielded: yes
Cable type: Ethernet BETAtrans® railway application CAT7[94S]
Conductor structure: 4x2xAWG26/7; S/FTP
Signal runtime: 4.4 ns/m
Signal speed: 0.78 c
Conductor structure signal line: 7x 0.16 mm
AWG signal line: 26
Conductor cross section: 4x 2x 0.14 mm²
Wire diameter incl. insulation: 1.05 mm ±0.1mm
External cable diameter: 6.6 mm ±0.2mm
Outer sheath, material: PE-X
External sheath, color: black
Conductor material: Tin-plated Cu litz wires
Material wire insulation: Cell PE
Single wire, color: white-blue, white-orange, white-green, white-brown
Twisted pairs: 2 cores to the pair
Type of pair shielding: Aluminum-lined polyester foil
Overall twist: 4 pairs, twisted
Max. conductor resistance: ≤ 145 Ω/km
Insulation resistance: ≥ 5 GΩ*km
Coupling resistance: 5.00 mΩ/m (at 10 MHz)
Wave impedance: 100 Ω ±5Ω (at 100 MHz)
Working capacitance: 44 nF (per kilometer)
Nominal voltage, cable: 125 VAC (Uo)
Test voltage Core/Core: 1000 VAC (50Hz, 1min.)
Test voltage Core/Shield: 1000 VAC (50Hz, 1min.)
Minimum bending radius, fixed installation: 6 x D
Tensile strength: ≤ 60 N (temporary)
≤ 15 N (Permanent)
Near end crosstalk attenuation (NEXT): 100 dB (with 1 MHz)
99 dB (at 10 MHz)
95 dB (at 100 MHz)
92 dB (at 200 MHz)
90 dB (at 250MHz)
83 dB (at 500MHz)
81 dB (at 600MHz)
80 dB (at 700MHz)
77 dB (at 800MHz)
75 dB (at 900MHz)
74 dB (at 1000 MHz)
72 dB (at 1100MHz)
70 dB (at 1200MHz)
Power-summated near end crosstalk attenuation (PSNEXT): 97 dB (with 1 MHz)
96 dB (at 10 MHz)
92 dB (at 100 MHz)
89 dB (at 200 MHz)
87 dB (at 250MHz)
80 dB (at 500MHz)
78 dB (at 600MHz)
77 dB (at 700MHz)
74 dB (at 800MHz)
72 dB (at 900MHz)
71 dB (at 1000 MHz)
69 dB (at 1100MHz)
67 dB (at 1200MHz)
Return attenuation (RL): 24 dB (with 1 MHz)
33.9 dB (at 10 MHz)
38.3 dB (at 100 MHz)
35.3 dB (at 200 MHz)
32.9 dB (at 250MHz)
29.7 dB (at 500MHz)
30.6 dB (at 600MHz)
31 dB (at 700MHz)
26.7 dB (at 800MHz)
28.6 dB (at 900MHz)
27.5 dB (at 1000 MHz)
26.9 dB (at 1100MHz)
26.3 dB (at 1200MHz)
Crosstalk attenuation (ACR): 100 dB (with 1 MHz)
99 dB (at 10 MHz)
93 dB (at 100 MHz)
88 dB (at 200 MHz)
86 dB (at 250MHz)
78 dB (at 500MHz)
74 dB (at 600MHz)
72 dB (at 700MHz)
69 dB (at 800MHz)
67 dB (at 900MHz)
65 dB (at 1000 MHz)
63 dB (at 1100MHz)
61 dB (at 1200MHz)
Power-summated crosstalk attenuation (PS-ACR): 97 dB (with 1 MHz)
96 dB (at 10 MHz)
90 dB (at 100 MHz)
85 dB (at 200 MHz)
83 dB (at 250MHz)
75 dB (at 500MHz)
71 dB (at 600MHz)
69 dB (at 700MHz)
66 dB (at 800MHz)
64 dB (at 900MHz)
62 dB (at 1000 MHz)
60 dB (at 1100MHz)
58 dB (at 1200MHz)
Shield attenuation: 0.25 dB (with 1 MHz)
0.76 dB (at 10 MHz)
2.49 dB (at 100 MHz)
3.69 dB (at 200 MHz)
4.18 dB (at 250MHz)
5.6 dB (at 500MHz)
6.74 dB (at 600MHz)
7.32 dB (at 700MHz)
7.89 dB (at 800MHz)
8.5 dB (at 900MHz)
9.11 dB (at 1000 MHz)
9.5 dB (at 1100MHz)
9.9 dB (at 1200MHz)
60 dB (up to 1000 MHz)
Halogen-free: in accordance with EN 50267-2-1
in accordance with EN 60684-2
Flame resistance: in accordance with EN60332-1-2
EN60332-3-25
in accordance with ISO 14572 5.21 (UN ECE-R 118.01)
Concentration of fumes: EN 61034-2
Resistance to oil: in accordance with EN 50306-4, 72 hours at 100°C, IRM 902
Fire protection in rail vehicles: BS6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
DIN5510-2 (Fire protection level 1, 2, 3, 4)
EN45545-2
EN50306-4
NFF16-101 (Classification C/F1)
NFF16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
NFPA130
PN-K-02511 (ClassA)
UIC564-2 (ClassA)
Other resistance: Resistant to fuel in accordance with EN50306-4, 168 hours at 70°C, IRM 903
Resistant to ozone in accordance with EN50306-4, 72 hours at 40°C, method B, volumetric concentration of 200 x 10-6
Special properties: HL1-HL3
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65/IP67
Standards and regulationsM12
Standard designation: M12 connector
Shock, vibration
Standards/specifications: IEC 61076-2-109
EN50155
Technical Specs
ECLASSECLASS-11.0: 27060307
ECLASS-12.0: 27060307
ECLASS-13.0: 27060307
ETIMETIM 9.0: EC001855
UNSPSCUNSPSC 21.0: 26121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manufacturer_declaration_00216.pdf

Manufacturer_declaration_02419.pdf

Manufacturer_declaration_05519.pdf