Product properties | Product type: Data cable by the meter Sensor type: Ethernet Number of positions: 8 Application: Drag chain Shielded: yes |
Electrical properties | Transmission medium: Copper |
Interfaces | Signal type/category: Ethernet CAT5 (IEC 11801), 1 Gbps |
Connector | Connection 1 Type: free cable end Connection 2 Type: free cable end |
Cable/line | Cable length: 100 m Ethernet drag chain CAT5, 4-pair[94C] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/7d8f0a2df9771f40aac7b9675a7fbd3f/-S204x204-FJPG Cable weight: 57 kg/km UL AWM Style: 20963 (80°C/30 V) Number of positions: 8 Shielded: yes Cable type: Ethernet drag chain CAT5, 4-pair[94C] Conductor structure: 4x2xAWG26/19, S/UTP Signal runtime: 5.3 ns/m Conductor structure signal line: 19x 0.10 mm AWG signal line: 26 Conductor cross section: 4x 2x 0.14 mm² Wire diameter incl. insulation: 1 mm External cable diameter: 6.9 mm +0.1mm ... 0.2mm Outer sheath, material: PUR External sheath, color: water blue RAL5021 Conductor material: Bare Cu litz wires Material wire insulation: PP Single wire, color: white/blue-blue, white/orange-orange, white/green-green, white/brown-brown Thickness, outer sheath: 0.85 mm Twisted pairs: 2 cores to the pair Overall twist: Four pairs and four fillers to the core Optical shield covering: 90 % Insulation resistance: ⥠500 Mé*km Coupling resistance: ⤠100.00 mé/m (at 10 MHz) Loop resistance: ⤠290.00 é/km Wave impedance: 100 é ±5é (at 100 MHz) Cable capacity: approx. 50 nF/km (at 1 kHz) Nominal voltage, cable: ⤠100 V Test voltage Core/Core: 700 V (50Hz, 1min.) Test voltage Core/Shield: 700 V (50Hz, 1min.) Minimum bending radius, fixed installation: 4 x D Minimum bending radius, flexible installation: 8 x D Max. bending cycles: 5000000 Tensile strength: ⤠100 N Near end crosstalk attenuation (NEXT): 65.3 dB (with 1 MHz) 56.3 dB (at 4 ÃHz) 50.3 dB (at 10 MHz) 47.2 dB (at 16 MHz) 45.8 dB (at 20ÃHz) 42.9 dB (at 31.25ÃHz) 38.4 dB (at 62.5ÃHz) 35.3 dB (at 100 MHz) Power-summated near end crosstalk attenuation (PSNEXT): 62.3 dB (with 1 MHz) 53.3 dB (at 4 ÃHz) 47.3 dB (at 10 MHz) 44.2 dB (at 16 MHz) 42.8 dB (at 20ÃHz) 39.9 dB (at 31.25ÃHz) 35.4 dB (at 62.5ÃHz) 32.3 dB (at 100 MHz) Return attenuation (RL): 23 dB (at 4 ÃHz) 24.1 dB (at 8ÃHz) 25 dB (at 10 MHz) 25 dB (at 16 MHz) 25 dB (at 20ÃHz) 23.6 dB (at 31.25ÃHz) 21.5 dB (at 62.5ÃHz) 20.1 dB (at 100 MHz) Shield attenuation: 3.2 dB (with 1 MHz) 6 dB (at 4 ÃHz) 9.5 dB (at 10 MHz) 12.1 dB (at 16 MHz) 13.6 dB (at 20ÃHz) 17.1 dB (at 31.25ÃHz) 24.8 dB (at 62.5ÃHz) 32 dB (at 100 MHz) Halogen-free: according to IEC 60754-1 Flame resistance: according to IEC 60332-1-2 Resistance to oil: in accordance with EN 60811-2-1 Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation) -20°C ... 80°C (Cable, flexible installation) Ambient temperature (installation): -20°C ... 80°C |
ECLASS | ECLASS-11.0: 27061801 ECLASS-12.0: 27061801 ECLASS-13.0: 27061801 |
ETIM | ETIM 9.0: EC003249 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products