HC-M-DSUB 09-CT-M - Contact insert module
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Notes | General: Connectors may be operated only when there is no load/voltage. The use of guide pins (HC-CST) and sockets (HC-CBU) is recommended to prevent tip collision due to misalignment. |
Mounting | Assembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required Pin8=B Pin3=A Connection method: Crimp connection |
Product properties | Product type: Modular contact insert Number of positions: 9 Connection profile: 9 Contact numbering: 1 - 9 Application: Data Number of module slots: 1 Type: D-SUB9 Contact material type: turned Series: HC-M-DSUB-C Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Connection data | Connection technology Connection technology: Crimp connection Clamping range of the strain relief clip: 4.00 mm ... 7.00 mm Conductor connection Conductor cross section: 0.08 mm² ... 0.5 mm² Connection cross section AWG: 28 ... 20 Stripping length of the individual wire: 4.2 mm |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/dc3e1c524db6a249b774b212f3826e9a/-S204x204-FJPG Width: 34.2 mm Height: 35.2 mm Length: 14.6 mm Clamping range of the strain relief clip: 4.00 mm ... 7.00 mm Mechanical characteristics Minimum housing height: 52 mm Contact diameter: 1 mm |
Electrical properties | Rated voltage (III/3): 48 V Rated surge voltage: 0.8 kV Rated current: 1 A |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ≥ 500 |
Material specifications | Material: Zinc alloy Flammability rating according to UL 94: V0 Contact material: Copper alloy Contact surface material: Ag Contact carrier material: PC Standards/regulations: PC: Fire protection in rail vehicles - requirement set R22 acc. to DINEN45545-2 (Risk level HL1 - HL2) PC: Fire protection in rail vehicles - requirement set R23 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 125°C |
Standards and regulations | Testing Standards/regulations: PC: Fire protection in rail vehicles - requirement set R22 acc. to DINEN45545-2 (Risk level HL1 - HL2) PC: Fire protection in rail vehicles - requirement set R23 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
ECLASS | ECLASS-11.0: 27440218 ECLASS-12.0: 27440218 ECLASS-13.0: 27440218 |
ETIM | ETIM 9.0: EC000438 |
UNSPSC | UNSPSC 21.0: 39121400 |