Industrial Automation
Notes | General: The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
Product properties | Product type: Contact insert Number of positions: 3 Seal present: yes Coding: A Thread type: M8 Insulation characteristics Overvoltage category: III |
Electrical properties | Contact resistance: ⤠3 mé Insulation resistance: ⤠100 Mé Nominal voltage UN: 60 V Nominal current IN: 3 A |
Material specifications | Flammability rating according to UL 94: V0 Seal material: FKM Contact material: CuZn Contact surface material: Au Contact carrier material: PA |
Connector | Connection 1 Head design: Pin Head cable outlet: straight Head thread type: M8 Coding: A |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: > 100 |
Environmental and real-life conditions | Ambient conditions Degree of protection (when plugged in): IP67 (correctly plugged in and locked) Degree of protection (not plugged in): IP65 (not plugged in, by means of additional O-ring seal with device) Degree of protection: IP67 Ambient temperature (operation): -25°C ... 105°C (Plug / socket) -40°C ... 105°C (without mechanical actuation) |
Standards and regulations | M8 Standard designation: M8 connector Standards/specifications: IEC 61076-2-104 |
Mounting | Mounting type: PCB mounting Connection method: SMD |