Industrial Automation
Product properties | Product type: Data cable by the meter Sensor type: Ethernet Number of positions: 8 Application: Railway applications |
Electrical properties | Nominal voltage UN: 30 VAC 30 VDC Transmission medium: Copper |
Interfaces | Signal type/category: Ethernet CAT7, 10 Gbps |
Cable/line | Cable length: 100 m Ethernet BETAtrans Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/1f08ac23481cba498cd37c88ad48a160/-S204x204-FJPG Cable weight: 59 kg/km Copper weight: 28 kg/km Number of positions: 8 Shielded: yes Cable type: Ethernet BETAtrans® railway application CAT7[94S] Conductor structure: 4x2xAWG26/7; S/FTP Signal runtime: 4.4 ns/m Signal speed: 0.78 c Conductor structure signal line: 7x 0.16 mm AWG signal line: 26 Conductor cross section: 4x 2x 0.14 mm² Wire diameter incl. insulation: 1.05 mm ±0.1mm External cable diameter: 6.6 mm ±0.2mm Outer sheath, material: PE-X External sheath, color: black Conductor material: Tin-plated Cu litz wires Material wire insulation: Cell PE Single wire, color: white-blue, white-orange, white-green, white-brown Twisted pairs: 2 cores to the pair Type of pair shielding: Aluminum-lined polyester foil Overall twist: 4 pairs, twisted Max. conductor resistance: ⤠145 é/km Insulation resistance: ⥠5 Gé*km Coupling resistance: 5.00 mé/m (at 10 MHz) Wave impedance: 100 é ±5é (at 100 MHz) Working capacitance: 44 nF (per kilometer) Nominal voltage, cable: 125 VAC (Uo) Test voltage Core/Core: 1000 VAC (50Hz, 1min.) Test voltage Core/Shield: 1000 VAC (50Hz, 1min.) Minimum bending radius, fixed installation: 6 x D Tensile strength: ⤠60 N (temporary) ⤠15 N (Permanent) Near end crosstalk attenuation (NEXT): 100 dB (with 1 MHz) 99 dB (at 10 MHz) 95 dB (at 100 MHz) 92 dB (at 200 MHz) 90 dB (at 250MHz) 83 dB (at 500MHz) 81 dB (at 600MHz) 80 dB (at 700MHz) 77 dB (at 800MHz) 75 dB (at 900MHz) 74 dB (at 1000 MHz) 72 dB (at 1100MHz) 70 dB (at 1200MHz) Power-summated near end crosstalk attenuation (PSNEXT): 97 dB (with 1 MHz) 96 dB (at 10 MHz) 92 dB (at 100 MHz) 89 dB (at 200 MHz) 87 dB (at 250MHz) 80 dB (at 500MHz) 78 dB (at 600MHz) 77 dB (at 700MHz) 74 dB (at 800MHz) 72 dB (at 900MHz) 71 dB (at 1000 MHz) 69 dB (at 1100MHz) 67 dB (at 1200MHz) Return attenuation (RL): 24 dB (with 1 MHz) 33.9 dB (at 10 MHz) 38.3 dB (at 100 MHz) 35.3 dB (at 200 MHz) 32.9 dB (at 250MHz) 29.7 dB (at 500MHz) 30.6 dB (at 600MHz) 31 dB (at 700MHz) 26.7 dB (at 800MHz) 28.6 dB (at 900MHz) 27.5 dB (at 1000 MHz) 26.9 dB (at 1100MHz) 26.3 dB (at 1200MHz) Crosstalk attenuation (ACR): 100 dB (with 1 MHz) 99 dB (at 10 MHz) 93 dB (at 100 MHz) 88 dB (at 200 MHz) 86 dB (at 250MHz) 78 dB (at 500MHz) 74 dB (at 600MHz) 72 dB (at 700MHz) 69 dB (at 800MHz) 67 dB (at 900MHz) 65 dB (at 1000 MHz) 63 dB (at 1100MHz) 61 dB (at 1200MHz) Power-summated crosstalk attenuation (PS-ACR): 97 dB (with 1 MHz) 96 dB (at 10 MHz) 90 dB (at 100 MHz) 85 dB (at 200 MHz) 83 dB (at 250MHz) 75 dB (at 500MHz) 71 dB (at 600MHz) 69 dB (at 700MHz) 66 dB (at 800MHz) 64 dB (at 900MHz) 62 dB (at 1000 MHz) 60 dB (at 1100MHz) 58 dB (at 1200MHz) Shield attenuation: 0.25 dB (with 1 MHz) 0.76 dB (at 10 MHz) 2.49 dB (at 100 MHz) 3.69 dB (at 200 MHz) 4.18 dB (at 250MHz) 5.6 dB (at 500MHz) 6.74 dB (at 600MHz) 7.32 dB (at 700MHz) 7.89 dB (at 800MHz) 8.5 dB (at 900MHz) 9.11 dB (at 1000 MHz) 9.5 dB (at 1100MHz) 9.9 dB (at 1200MHz) 60 dB (up to 1000 MHz) Halogen-free: in accordance with EN 50267-2-1 in accordance with EN 60684-2 Flame resistance: in accordance with EN60332-1-2 EN60332-3-25 in accordance with ISO 14572 5.21 (UN ECE-R 118.01) Concentration of fumes: EN 61034-2 Resistance to oil: in accordance with EN 50306-4, 72 hours at 100°C, IRM 902 Fire protection in rail vehicles: BS6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II) DIN5510-2 (Fire protection level 1, 2, 3, 4) EN45545-2 EN50306-4 NFF16-101 (Classification C/F1) NFF16-101 (Internal cable A1, A2, B/external cable A1, A2, B) NFPA130 PN-K-02511 (ClassA) UIC564-2 (ClassA) Other resistance: Resistant to fuel in accordance with EN50306-4, 168 hours at 70°C, IRM 903 Resistant to ozone in accordance with EN50306-4, 72 hours at 40°C, method B, volumetric concentration of 200 x 10-6 Special properties: HL1-HL3 Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation) |
ECLASS | ECLASS-11.0: 27061801 ECLASS-13.0: 27061801 |
ETIM | ETIM 9.0: EC003249 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products