Industrial Automation
Notes | General: NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g.by using cable ties. |
Mounting | Assembly instructions: The wires can be connected both with ferrules and without ferrules Connection method: Push-lock spring connection |
Product properties | Product type: Circular connector (cable-side) Sensor type: PROFINET Number of positions: 4 Application: Data No. of cable outlets: 1 Shielded: yes Coding: D Cable outlet: straight Insulation characteristics Overvoltage category: II Degree of pollution: 3 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9952fa0528af9c4fb6d3f3d03cd70fde/-S204x204-FJPG Length: 59 mm External dimensions Outside diameter: 4 mm ... 8 mm Housing Diameter housing: 19 mm |
Material specifications | Material: TPE-U PA 6 Flammability rating according to UL 94: V0 Seal material: NBR Material of grip body: Zinc die-cast, nickel-plated Contact material: CuSn Contact surface material: Ni/Au Contact carrier material: PA 6.6 Material for screw connection: Zinc die-cast, nickel-plated Standards/regulations: PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, R25, and R26 acc. to DINEN45545-2 (Risk level HL1 - HL3) PA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
Connection data | Conductor connection Connection method: Push-lock spring connection Connection cross section: 0.14 mm² ... 0.75 mm² (without ferrule) 0.08 mm² ... 0.5 mm² (with ferrule) 0.14 mm² ... 0.75 mm² (solid) Connection cross section AWG: 26 ... 18 (without ferrule) 28 ... 20 (with ferrule) Stripping length of the individual wire: 7 mm Tightening torque: 0.4 Nm (M12 knurl) 0.8 Nm (Connector with coupling sleeve) 3 Nm (Pressure nut with coupling sleeve) Pin assignment Contact | Color (signal designation) | Contact (optional): 1 = YE (TD+) 2 = WH (RD+) 3 = OG (TD-) 4 = BU (RD-) |
Electrical properties | Rated surge voltage: 1.5 kV Contact resistance: ⤠5 mé Insulation resistance: ⥠100 Mé Nominal voltage UN: 48 VAC 60 VDC Nominal current IN: 4 A (2A when using 0.14mm² conductors) |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠100 (Quantity: 500 with Phoenix Contact mating connector) |
Connector | Connection 1 Head design: Socket Head cable outlet: straight Head thread type: M12 Coding: D |
Cable/line | Signal type/category: PROFINET CAT5 (based on IEC 11801), 100 Mbps Stripping length of the individual wire: 7 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 IP67 Ambient temperature (operation): -40°C ... 85°C (Plug / socket) |
Standards and regulations | Testing Standards/regulations: PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, R25, and R26 acc. to DINEN45545-2 (Risk level HL1 - HL3) PA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) M12 Standard designation: M12 connector Shock, vibration Standards/specifications: IEC 61076-2-101 EN50155:2001 |