Industrial Automation
Notes | General: The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Lock nut is included in the scope of delivery |
Mounting | Mounting type: Rear mounting M16 x 1.5 Tightening limitation Assembly instructions: Tightening limitation Connection method: Individual wires |
Product properties | Product type: Circular connectors (device side) Sensor type: Power Number of positions: 4 No. of cable outlets: 1 Shielded: no Coding: L Thread type: M12 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Material specifications | Flammability rating according to UL 94: V0 Seal material: FKM Contact material: CuZn Contact surface material: Au Contact carrier material: PA Material for screw connection: Zinc die-cast, nickel-plated Conductor material: Tin-plated Cu litz wires |
Electrical properties | Rated surge voltage: 1.5 kV 1.5 kV AC/DC Nominal voltage UN: 63 VDC Nominal current IN: 16 A Test voltage: 1.5 kV |
Connection data | Conductor connection Connection method: Individual wires Contact connection type: Pin Conductor cross section: 2.5 mm² |
Connector | Connection 1 Head design: Pin Head cable outlet: straight Head thread type: M12 Head locking type: Standard Coding: L Connection 2 Head design: free cable end |
Cable/line | Cable length: 0.2 m Cable type: PEX litz wire Signal type/category: Power Single wire, color: brown 1, white 2, blue 3, black 4 Cable cross section: 2.5 mm² Conductor material: Tin-plated Cu litz wires AWG signal line: 14 Material wire insulation: PE-X Halogen-free: according to IEC 60754-1 Flame resistance: in acc. with UL FT-2 Ambient temperature (operation): -40°C ... 85°C (without mechanical actuation) -25°C ... 105°C (Cable, flexible installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP67 IP65/IP67 Ambient temperature (operation): -25°C ... 85°C (Plug / socket) -40°C ... 85°C (without mechanical actuation) -25°C ... 105°C (Cable, flexible installation) -40°C ... 105°C (cable, fixed installation) |
Standards and regulations | Flame resistance: in acc. with UL FT-2 M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-111 Note: In line with |
ECLASS | ECLASS-11.0: 27440102 ECLASS-12.0: 27440116 ECLASS-13.0: 27440116 |
ETIM | ETIM 9.0: EC002635 |
UNSPSC | UNSPSC 21.0: 39121400 |
Description other products