PHOENIX CONTACT 1426513
PHOENIX CONTACTNot available

SACCEC-M12FSB-5CON-M16/20,0-920 - Device connector front mounting

Device connector front mounting, 5-position, coding: B, M16 x 1.5, Bus line, Alternative product in accordance with RoHS II without Exemption6c (Pb<0.1%) item no.: 1239590
Product Code: 1426513
Partner cod.: 1426513
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral: Lock nut is included in the scope of delivery
Safety note
Safety note: WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by PhoenixContact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
MountingMounting type: Front wall/screw mounting, can be positioned
Connection method: Bus line
Product propertiesProduct type: Circular connectors (device side)
Number of positions: 5
Coding: B
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Electrical propertiesRated surge voltage: 1.5 kV AC
Nominal voltage UN: 48 VAC
60 VDC
Nominal current IN: 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Transmission medium: Copper
Connection dataConductor connection
Connection method: Bus line
Cable/lineCable length: 20
CANopen
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/fc78069afd463243880387c2e14a096e/-S204x204-FJPG
Cable weight: 90 kg/km
UL AWM Style: 21198 (80°C/300 V)
Number of positions: 4
Shielded: yes
Cable type: CANopen®/DeviceNet™, PUR, violet[920]
Conductor structure: 2xAWG24/19+2xAWG22/19
Conductor structure signal line: 19x 0.13 mm
AWG signal line: 24
Conductor cross section: 2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation: 1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter: 6.7 mm ±0.3mm
Outer sheath, material: PUR
External sheath, color: red lilac RAL 4001
Conductor material: Tin-plated Cu litz wires
Material wire insulation: Foamed PE (Data cable)
PE (Power supply)
Single wire, color: red-black, blue-white
Twisted pairs: 2 cores to the pair
Type of pair shielding: Plastic-coated aluminum foil, aluminum side outside
Overall twist: 2 pairs around a drain wire in the center to the core
Optical shield covering: 80 %
Insulation resistance: ≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance: ≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance: 120 Ω ±10% (with 1 MHz)
Cable capacity: nom. 40 nF/km (Data cable)
Nominal voltage, cable: ≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core: 2000 V (50Hz, 1min.)
Test voltage Core/Shield: 2000 V (50Hz, 1min.)
Minimum bending radius, fixed installation: 5 x D
Minimum bending radius, flexible installation: 10 x D
Smallest bending radius, fixed installation: 34 mm
Smallest bending radius, movable installation: 67 mm
Max. bending cycles: 5000000
Shield attenuation: ≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-free: in accordance with DINVDE0472 part815
according to IEC 60754-1
Flame resistance: UL1581, Section 1060 and UL2556, Section 9.3 (FT1)
UL1581, Section 1100 and UL2556, Section 9.1 (HFT/FT2)
IEC 60332-1-2
in accordance with ISO6722-1 5.22 (UN ECE-R 118.01)
Other resistance: Low adhesion
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
-30°C ... 70°C (Cable, flexible installation)
-20°C ... 60°C (for installation)
-20°C ... 60°C (cable, drag chain applications)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP67
Ambient temperature (operation): -25 ... -85
Standards and regulationsStandards/specifications: according to IEC 61076-2-101
Technical Specs
ECLASSECLASS-11.0: 27440102
ECLASS-12.0: 27440116
ECLASS-13.0: 27440116
ETIMETIM 8.0: EC002635
UNSPSCUNSPSC 21.0: 39121400
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00962.pdf

Design-In_00003.pdf

Manufacturer_declaration_01327.pdf

Manufacturer_declaration_02386.pdf

Manufacturer_declaration_05485.pdf

Manufacturer_declaration_08432.pdf

Technical_drawing_12710.pdf