PHOENIX CONTACTNot available

SAC-5PY-F/2X 0,3-920-MS-FS - Bus system cable

Bus system cable, CANopen®, DeviceNet™, 5-position halogen-free, shielded, Socket straight M12, coding: A SPEEDCON, on Socket straight M12, coding: A SPEEDCON and Plug straight M12, coding: A SPEEDCON, cable length: 0.3 m, all connectors unshielded, Shield connected to pin 1
Product Code: 1436013
Partner cod.: 1436013
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Data cable preassembled
Sensor type: CANopen®
Number of positions: 5
Application: Standard
No. of cable outlets: 1
Shielded: no
Coding: A
Insulation characteristics
Overvoltage category: II
Degree of pollution: 3
InterfacesBus system: CANopen®/DeviceNet™
Signal type/category: CANopen®
DeviceNet™
SignalingStatus display: No
Status display present: No
Electrical propertiesContact resistance: ≤ 5 mΩ
Insulation resistance: ≥ 100 MΩ
Nominal voltage UN: 48 VAC
60 VDC
Nominal current IN: 4 A
Transmission medium: Copper
Material specificationsFlammability rating according to UL 94: HB
Seal material: NBR
Material of grip body: TPU, hardly inflammable, self-extinguishing
Contact material: CuSn
Contact surface material: Ni/Au
Contact carrier material: TPU GF
Material for screw connection: Zinc die-cast, nickel-plated
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/2fcc936e7f1dd647a08d20113593a631/-S204x204-FJPG
Center distance: 21 mm
Connection dataPin assignment
Contact | Color (signal designation) | Contact (optional): 1 (Distributor) | SR (shield) | 1 (Plug)| 1 (Socket)
2 (Distributor) | RD (V+) | 2 (Plug)| 2 (Socket)
3 (Distributor) | BK (V-) | 3 (Plug)| 3 (Socket)
4 (Distributor) | WH (CAN_H) | 4 (Plug)| 4 (Socket)
5 (Distributor) | BU (CAN_L) | 5 (Plug)| 5 (Socket)
ConnectorConnection 1
Type: Socket straight M12 SPEEDCON
Number of positions: 5
Coding type: A (Standard)
Ambient temperature (operation): -25°C ... 90°C
Locking type: SPEEDCON
Connection 2
Type: Socket straight M12 SPEEDCON
Number of positions: 5
Coding type: A (Standard)
Ambient temperature (operation): -25°C ... 90°C
Locking type: SPEEDCON
Cable/lineCable length: 0.3 m
CANopen
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/fc78069afd463243880387c2e14a096e/-S204x204-FJPG
Cable weight: 90 kg/km
UL AWM Style: 21198 (80°C/300 V)
Number of positions: 4
Shielded: yes
Cable type: CANopen®/DeviceNet™, PUR, violet[920]
Conductor structure: 2xAWG24/19+2xAWG22/19
Conductor structure signal line: 19x 0.13 mm
AWG signal line: 24
Conductor cross section: 2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation: 1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter: 6.7 mm ±0.3mm
Outer sheath, material: PUR
External sheath, color: red lilac RAL 4001
Conductor material: Tin-plated Cu litz wires
Material wire insulation: Foamed PE (Data cable)
PE (Power supply)
Single wire, color: red-black, blue-white
Twisted pairs: 2 cores to the pair
Type of pair shielding: Plastic-coated aluminum foil, aluminum side outside
Overall twist: 2 pairs around a drain wire in the center to the core
Optical shield covering: 80 %
Insulation resistance: ≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance: ≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance: 120 Ω ±10% (with 1 MHz)
Cable capacity: nom. 40 nF/km (Data cable)
Nominal voltage, cable: ≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core: 2000 V (50Hz, 1min.)
Test voltage Core/Shield: 2000 V (50Hz, 1min.)
Minimum bending radius, fixed installation: 5 x D
Minimum bending radius, flexible installation: 10 x D
Smallest bending radius, fixed installation: 34 mm
Smallest bending radius, movable installation: 67 mm
Max. bending cycles: 5000000
Shield attenuation: ≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-free: in accordance with DINVDE0472 part815
according to IEC 60754-1
Flame resistance: IEC 60332-1-2
in accordance with ISO6722-1 5.22 (UN ECE-R 118.01)
Other resistance: Low adhesion
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
-30°C ... 70°C (Cable, flexible installation)
-20°C ... 60°C (for installation)
-20°C ... 60°C (cable, drag chain applications)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65
IP67
Standards and regulationsStandard designation: M12 connector
Standards/specifications: IEC 61076-2-101
Technical Specs
ECLASSECLASS-11.0: 27060307
ECLASS-12.0: 27060307
ECLASS-13.0: 27060307
ETIMETIM 9.0: EC001855
UNSPSCUNSPSC 21.0: 26121600
Description
Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, violet RAL 4001, shielded, Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 0.3 m, all connectors unshielded, Shield connected to pin 1
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manufacturer_declaration_00215.pdf

Manufacturer_declaration_02453.pdf

Manufacturer_declaration_05516.pdf