Industrial Automation
Product properties | Product type: Data cable preassembled Sensor type: Ethernet Number of positions: 4 Application: External areas No. of cable outlets: 1 Shielded: yes Coding: D Insulation characteristics Degree of pollution: 3 |
Interfaces | Bus system: PROFINET Ethernet Signal type/category: Ethernet CAT5 (IEC 11801), 100 Mbps PROFINET CAT5 (IEC 11801), 100 Mbps |
Signaling | Status display: No Status display present: No |
Electrical properties | Nominal voltage UN: 48 VAC 60 VDC Nominal current IN: 4 A Transmission medium: Copper |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠100 |
Material specifications | Flammability rating according to UL 94: V0 |
Connector | Connection 1 Type: Plug straight M12 / IP69K Number of positions: 4 (4) 4 Coding type: D (Data) Shielded: yes Handle color: black Material: CuZn (Contact) Ni/Au (Contact surface) PA (Contact carriers) TPU, hardly inflammable, self-extinguishing (Grip) Zinc die-cast, nickel-plated (Screw connection) FPM Degree of protection: IP69K Connection 2 Type: free cable end Number of positions: 4 |
Cable/line | Cable length: 10 m PROFINET outdoors[93X] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/35eeeb11fbacdc4187dc972d16fa1966/-S204x204-FJPG Cable weight: 81 g/m Shielded: yes Cable type: PROFINET outdoors[93X] Conductor structure: 1x4xAWG22/7, SF/TQ Signal speed: 66 c Conductor structure signal line: 7x 0.25 mm AWG signal line: 22 Conductor cross section: 4x 0.34 mm² Wire diameter incl. insulation: 1.95 mm External cable diameter: 7.25 mm ±0.3mm Outer sheath, material: PE-X External sheath, color: black RAL9005 Conductor material: silver-plated Cu litz wires Material wire insulation: PE-X Single wire, color: white-blue, orange-yellow Thickness, outer sheath: ⥠0.8 mm Overall twist: Star quad Optical shield covering: 100 % Max. conductor resistance: ⤠54.4 é/km Coupling resistance: 200.00 mé/m (f ⤠30 MHz) Wave impedance: 100 é ±5é (f = 100 MHz) Working capacitance: ⤠65 pF (Line-line) ⤠100 pF (Line-shield) Nominal voltage, cable: 300 VAC Test voltage: 2000 VAC (50 Hz, 5 minutes) Minimum bending radius, fixed installation: 6 x D Minimum bending radius, flexible installation: 10 x D Shield attenuation: 40 dB (30 MHz ⤠f ⤠100 MHz) Halogen-free: in accordance with EN 50267-2-1 Flame resistance: EN60332-1-2 EN50266 EN60332-3-25 NFC32-070, 2.1 NFC32-070, 2.2 UL1685, 12 (FT4) in accordance with ISO6722-1 5.22 (UN ECE-R 118.01) Fume corrosiveness: EN50267-2-2 Fume toxicity: BS6853 B.1 EN50305, 9.2 Concentration of fumes: BS 6853 D.8.7 EN 61034-2 UL 1685, 12 (FT4) Resistance to oil: according to IRM 902, 72 h at 100°C Fire protection in rail vehicles: BS6853 (Category Ia, Ib, II) GM/RT2130 (Category Ia, Ib, II) EN45545 (Risk level HL1 - HL3) DIN5510 (Fire protection level 1, 2, 3, 4) NFF16-101 (Category A1, A2, B) NFF16-101 (Class C/F0) NFPA130 UNICEI11170 (Risk level LR1 - LR4) Other resistance: Resistance to fuels according to IRM 903, 168 h at 70°C Ambient temperature (operation): -50°C ... 90°C (cable, fixed installation) -40°C ... 90°C (Cable, flexible installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 IP67 IP68 IP69K Ambient temperature (operation): -40°C ... 105°C -40°C ... 90°C (cable, fixed installation) -25°C ... 90°C (Cable, flexible installation) -40°C ... 85°C (On sudden changes in temperature (according to IEC 60512-11-4)) |
Standards and regulations | M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-101 |
ECLASS | ECLASS-11.0: 27060307 ECLASS-12.0: 27060307 ECLASS-13.0: 27060307 |
ETIM | ETIM 9.0: EC001855 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products