Industrial Automation
Product properties | Product type: Sensor/actuator cable Number of positions: 4 Shielded: no Insulation characteristics Overvoltage category: II Degree of pollution: 3 |
Material specifications | Seal material: NBR Material of grip body: TPU, hardly inflammable, self-extinguishing Contact material: CuSn Contact surface material: Ni/Au Contact carrier material: TPU GF Material for screw connection: Zinc die-cast, nickel-plated |
Electrical properties | Nominal voltage UN: 250 VAC 250 VDC Nominal current IN: 4 A |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠100 |
Connection data | Conductor connection Tightening torque: 0.4 Nm |
Connector | Connection 1 Type: free cable end Connection 2 Type: Socket angled M12 Number of positions: 4 |
Cable/line | Cable length: 5 m PUR halogen-free yellow[240] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e44bed04e8c9d64bab4de745b4f0aadb/-S204x204-FJPG Cable weight: 30 kg/km Number of positions: 4 Shielded: no Cable type: PUR halogen-free yellow[240] Conductor structure signal line: 42x 0.10 mm AWG signal line: 22 Conductor cross section: 4x 0.34 mm² Wire diameter incl. insulation: 1.27 mm ±0.02mm External cable diameter: 4.7 mm ±0.15mm Outer sheath, material: PUR External sheath, color: yellow Conductor material: Bare Cu litz wires Material wire insulation: PP Single wire, color: brown, white, blue, black Thickness, insulation: ⥠0.21 mm (Core insulation) approx. 0.8 mm (Outer cable sheath) Overall twist: 4 wires, twisted Length of twist, overall twist: 49.5 mm Max. conductor resistance: max. 58 é/km (at 20°C) Insulation resistance: ⥠1 Gé*km (at 20°C) Nominal voltage, cable: ⤠300 V Test voltage: ⥠3000 V Smallest bending radius, fixed installation: 23.5 mm Smallest bending radius, movable installation: 47 mm Max. bending cycles: 4000000 Halogen-free: in accordance with DINVDE0472 part815 in accordance with DINEN50267-2-1 Flame resistance: in accordance with DIN UL-Style 20549 in accordance with FT1 as per UL758 Resistance to oil: in accordance with DINEN60811-2-1 Other resistance: Highly resistant to acids, alkaline solutions and solvents hydrolysis and microbe resistant Special properties: Flexible cable conduit capable Silicone-free Free of substances which would hinder coating with paint or varnish Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation) -25°C ... 80°C (Cable, flexible installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 IP67 Ambient temperature (operation): -25°C ... 90°C (Plug / socket) -40°C ... 80°C (cable, fixed installation) -5°C ... 80°C (Cable, flexible installation) |
ECLASS | ECLASS-11.0: 27060311 ECLASS-12.0: 27060311 ECLASS-13.0: 27060311 |
ETIM | ETIM 8.0: EC001855 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products