Industrial Automation
Notes | General: The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Contact connection method: Crimp connection |
Mounting | Mounting type: Front mounting Pg9 Connection method: Individual wires |
Product properties | Product type: Circular connectors (device side) Sensor type: Universal Number of positions: 8 Application: Signal No. of cable outlets: 1 Shielded: no Coding: A Thread type: M12 Insulation characteristics Overvoltage category: II Degree of pollution: 3 |
Material specifications | Flammability rating according to UL 94: V0 Seal material: FKM Contact material: Cu alloy Contact surface material: Au Contact carrier material: PA 66 GF Material for screw connection: Stainless steel Conductor material: Tin-plated Cu litz wires |
Electrical properties | Rated surge voltage: 0.8 kV Contact resistance: ⤠3 mé Insulation resistance: > 100 Mé Nominal voltage UN: 30 V (AC) 30 V (DC) Nominal current IN: 2 A Max. conductor resistance: 80 é/km |
Connection data | Conductor connection Connection method: Individual wires Contact connection type: Pin Conductor cross section: 0.25 mm² Tightening torque: 3 Nm 4 Nm |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: > 100 |
Connector | Connection 1 Head design: Pin Head cable outlet: straight Head thread type: M12 Head locking type: Standard Coding: A Connection 2 Head design: free cable end |
Cable/line | Cable length: 0.5 m Cable type: TPE litz wire Signal type/category: Universal Wire diameter incl. insulation: 1.15 mm ±0.07mm Single wire, color: brown, blue, white, gray, pink, green, yellow, red Cable cross section: 0.25 mm² Conductor material: Tin-plated Cu litz wires Conductor structure signal line: 14x 0.15 mm AWG signal line: 24 Material wire insulation: TPE Thickness, insulation: 0.21 mm Nominal voltage, cable: 300 V Test voltage, cable: 2000 VAC Cable resistance: ⤠80 é/km Cable insulation resistance: ⥠20 Mé*km Ambient temperature (operation): -40°C ... 85°C (cable, fixed installation) -25°C ... 85°C (Cable, flexible installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65/IP67/IP69/IP69K IP65/IP67/IP69K Ambient temperature (operation): -25°C ... 85°C (Plug / socket) -40°C ... 85°C (without mechanical actuation) -25°C ... 85°C (Cable, flexible installation) -40°C ... 85°C (cable, fixed installation) |
Standards and regulations | Standard designation: M12 connector Standards/specifications: IEC 61076-2-101 |
Description other products