Industrial Automation
Notes | General: for housing HC-D7 Connectors may be operated only when there is no load/voltage. |
Mounting | Assembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required Already includes one IP65 sealing screw |
Product properties | Type: D7 Product type: Contact insert with a fixed no. of positions Number of positions: 4 Connection profile: 4+PE Contact numbering: 1 - 4 Number of connections per position: 1 Contact material type: turned Series: HC-A Screwdriver blade: 0.4 x 2.5 mm Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/c66bb72f54a25145b90a090eee8cdfb9/-S204x204-FJPG Width: 28 mm Height: 28.5 mm Length: 21 mm Mechanical characteristics Contact diameter: 1.6 mm |
Connection data | Connection technology Connection technology: Screw connection Number of connections per position: 1 Connection in acc. with standard: IEC / EN Conductor connection Conductor cross section: 0.5 mm² ... 2.5 mm² Connection cross section AWG: 20 ... 14 Tightening torque: 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) 0.25 Nm ... 0.5 Nm Stripping length of the individual wire: 5 mm |
Electrical properties | Rated voltage (III/3): 230 V (Conductor-PE) 400 V (Conductor-Conductor) Rated voltage for power contacts: 230/400 V Rated surge voltage: 4 kV Rated current: 10 A SCCR: 5 kA (UL 2237) |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠500 |
Material specifications | Flammability rating according to UL 94: V0 Contact material: Copper alloy Contact surface material: Ag Contact carrier material: PC Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 125°C (including heating up of contacts) |
Standards and regulations | Constructional and testing regulations: IEC 61984:2008 IEC 60664-1:2007 IEC 60664-1, DINIEC 60512 Tests: IEC 61984:2008 IEC 60664-1:2007 IEC 60664-1, DINIEC 60512 Testing Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
ECLASS | ECLASS-11.0: 27440205 ECLASS-12.0: 27440205 ECLASS-13.0: 27440205 |
ETIM | ETIM 9.0: EC000438 |
UNSPSC | UNSPSC 21.0: 39121500 |
Description other products