Notes | General: for HC-D25 / HC-D50 housing, crimp contact CK2,5-ED (crimp contacts not included in scope of supply) Connectors may be operated only when there is no load/voltage. |
Mounting | Assembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required for plastic coding profiles: 4 pcs. |
Product properties | Type: D25 D50 Product type: Contact insert with a fixed no. of positions Number of positions: 16 Connection profile: 16+PE Contact numbering: 17 - 32 Number of connections per position: 1 Contact material type: turned Series: HC-A Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/01e61966befa6545ac0d3c231c34e5e3/-S204x204-FJPG Width: 23 mm Height: 33 mm Length: 72 mm Drill hole distance, horizontal: 66 mm Drill hole distance, vertical: 16 mm Mechanical characteristics Contact diameter: 2.5 mm |
Connection data | Connection technology Connection technology: Crimp connection Number of connections per position: 1 Connection in acc. with standard: IEC / EN Conductor connection Conductor cross section: 0.5 mm² ... 4 mm² (applies to stranded conductors) Connection cross section AWG: 20 ... 12 Tightening torque: 0.7 Nm ... 1 Nm (PE connection) 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) Stripping length of the individual wire: 8 mm |
Electrical properties | Rated voltage (III/3): 250 V Rated surge voltage: 4 kV Rated current: 16 A |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠500 |
Material specifications | Contact material: Copper alloy Contact surface material: Ag (alternatively Au) Contact carrier material: PC Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 125°C (including heating up of contacts) |
Standards and regulations | Testing Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
ECLASS | ECLASS-11.0: 27440205 ECLASS-12.0: 27440205 ECLASS-13.0: 27440205 |
ETIM | ETIM 8.0: EC000438 |
UNSPSC | UNSPSC 21.0: 39121500 |