Industrial Automation
Product properties | Product type: Panel feed-through terminal block Product family: UWV 95 Number of positions: 1 Pitch: 25 mm Number of connections: 2 Number of potentials: 1 |
Electrical properties | Nominal current IN: 232 A Nominal voltage UN: 1000 V Degree of pollution: 3 Rated voltage (III/3): 1000 V Rated surge voltage (III/3): 8 kV Rated voltage (III/2): 1000 V Rated surge voltage (III/2): 8 kV Rated voltage (II/2): 1000 V Rated surge voltage (II/2): 6 kV |
Connection data | Connection technology Connector system: UW 95 Nominal cross section: 95 mm² Conductor connection exterior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: -90° Single-conductor/terminal point multi-stranded: 25 mm² ... 95 mm² Conductor cross section flexible: 35 mm² ... 95 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 25 mm² ... 95 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 25 mm² ... 95 mm² 2 conductors with the same cross section, stranded: 16 mm² ... 35 mm² 2 conductors with same cross section, flexible: 16 mm² ... 35 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 16 mm² ... 35 mm² Internal cylindrical gage: A12 / B12 Stripping length: 27 mm Tightening torque: 10 Nm ... 12 Nm Conductor connection interior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: 0° Single-conductor/terminal point multi-stranded: 25 mm² ... 95 mm² Conductor cross section flexible: 35 mm² ... 95 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 25 mm² ... 95 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 25 mm² ... 95 mm² 2 conductors with the same cross section, stranded: 16 mm² ... 35 mm² 2 conductors with same cross section, flexible: 16 mm² ... 35 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 16 mm² ... 35 mm² Internal cylindrical gage: A12 / B12 Stripping length: 27 mm Tightening torque: 10 Nm ... 12 Nm |
Mounting | Plate thickness: 1 mm ... 5 mm |
Material specifications | Material data - contact Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 Contact material: Al alloy Surface characteristics: tin-plated Material data - housing Color (Housing): gray (7042) Insulating material: PA Insulating material group: I CTI according to IEC 60112: 600 Flammability rating according to UL 94: V0 Glow wire flammability index GWFI according to EN60695-2-12: 850 Glow wire ignition temperature GWIT according to EN60695-2-13: 775 Temperature for the ball pressure test according to EN60695-10-2: 125°C |
Notes | Safety note Safety note: ⢠WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. ⢠The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product. ⢠The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection. |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e840d33717330747ad0c7b5d4b264f71/-S204x204-FJPG Pitch: 25 mm Width [w]: 25 mm External dimensions Width [w]: 25 mm Height [h1]: 73.9 mm Length [l1]: 45 mm Internal dimensions Width [w]: 25 mm Height [h2]: 79.5 mm Length [l2]: 78.7 mm |
Mechanical tests | Test for conductor damage and slackening Specification: IEC 60947-7-1:2009-04 Result: Test passed Pull-out test Specification: IEC 60947-7-1:2009-04 Conductor cross section/conductor type/tractive force setpoint/actual value: 25 mm² / stranded / > 135 N 35 mm² / flexible / > 190 N 95 mm² / stranded / > 351 N 95 mm² / flexible / > 351 N |
Electrical tests | Temperature-rise test Specification: IEC 60947-7-1:2009-04 Requirement temperature-rise test: Increase in temperature â¤45K Short-time withstand current Specification: IEC 60947-7-1:2009-04 Air clearances and creepage distances | 1. Insulation coordination Specification: IEC 60947-1:2007-06 + A1:2010-12 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 1000 V Rated surge voltage (III/3): 8 kV minimum clearance value - non-homogenous field (III/3): 8 mm minimum creepage distance (III/3): 12.5 mm Rated insulation voltage (III/2): 1000 V Rated surge voltage (III/2): 8 kV minimum clearance value - non-homogenous field (III/2): 8 mm minimum creepage distance (III/2): 8 mm Rated insulation voltage (II/2): 1000 V Rated surge voltage (II/2): 6 kV minimum clearance value - non-homogenous field (II/2): 5.5 mm minimum creepage distance (II/2): 5.5 mm |
Environmental and real-life conditions | Vibration test Specification: IEC 60068-2-6:2007-12 Frequency: 10 - 150 - 10 Hz Sweep speed: 1octave/min 5g (60.1Hz...150Hz) Amplitude: 0.35mm (10Hz...60.1Hz) Test duration per axis: 2.5 h Glow-wire test Specification: IEC 60695-2-11:2014-02 Temperature: 960°C Time of exposure: 30 s Ambient conditions Ambient temperature (operation): -40°C ... 100°C (Depending on the current carrying capacity/derating curve) Ambient temperature (storage/transport): -40°C ... 70°C Relative humidity (storage/transport): 30 % ... 70 % Ambient temperature (assembly): -5°C ... 100°C |
Packaging specifications | Type of packaging: packed in cardboard |
ECLASS | ECLASS-11.0: 27141134 ECLASS-13.0: 27141134 ECLASS-12.0: 27141134 |
ETIM | ETIM 9.0: EC001283 |
UNSPSC | UNSPSC 21.0: 39121400 |
Description other products