Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Product type: Extension module MTTF: 1065 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 449 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) 85 Years (Telcordia standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) Insulation characteristics Overvoltage category: II Degree of pollution: 2 |
Electrical properties | Electrical isolation: 500 VAC (NAMUR digital I/O - 50 Hz, 1 min, test voltage) Test voltage: 500 VAC (50Hz, 1min.) Maximum power dissipation for nominal condition: 1.54 W Supply Supply voltage range: 19.2 VDC ... 30.5 VDC (DIN rail connector) Max. current consumption: ⤠64 mA (At 24 V DC, at 25°C) |
Input data | Digital Non-load voltage: ~ 8 VDC Switching hysteresis: ⤠0.2 mA Digitalâ Description of the input: Digital input Number of inputs: 4 Available input sources: NAMUR proximity sensors (EN 60947-5-6) Floating switch contacts Switch contacts with resistance circuit Current input signal: ⤠1.2 mA (blocking) ⥠2.1 mA (conductive) Min. voltage input signal: 0 VDC Max. voltage input signal: 30.5 VDC Switching level "0" signal: 0 VDC ... 4 VDC Switching level "1" signal: 10 VDC ... 30.5 VDC |
Connection data | Connection method: Screw connection Stripping length: 7 mm Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 14 |
Signaling | Status display: Green LED (supply voltage, PWR) Green LED (bus communication, DAT) Red LED (periphery error, ERR) Yellow LED (digital input, DI1) Yellow LED (digital input, DI2) Yellow LED (digital input, DI3) Yellow LED (digital input, DI4) Red LED (Short circuit/Line break, E1) Red LED (Short circuit/Line break, E2) Red LED (Short circuit/Line break, E3) Red LED (Short circuit/Line break, E4) |
Dimensions | Width: 17.5 mm Height: 113 mm Depth: 114.5 mm |
Material specifications | Color: green Flammability rating according to UL 94: V0 Housing material: PA 6.6-FR |
Characteristics | Line fault detection: Break 0.05 mA < IIN < 0.35 mA Short circuit 100 é < RSensor < 360 é |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: 2000 m Permissible humidity (operation): 20 % ... 95 % (non-condensing) |
Approvals | Conformity/Approvals Conformance: CE-compliant CCC: Ex ec IIC T4 Gc Ex data ATEX: IBExU 17ATEXB011X; II 3 G; Ex ec IIC T4 Gc IECEx: IECEx IBE 17.0029X; Ex ec IIC T4 Gc UL, USA / Canada: Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, AEx ec IIC T4, Ex ec IIC T4 Gc X |
Standards and regulations | Standard designation: Ex Directive (ATEX) Standards/specifications: EN60079-0 |
ECLASS | ECLASS-11.0: 27242604 ECLASS-12.0: 27242604 ECLASS-13.0: 27242604 |
ETIM | ETIM 9.0: EC001599 |
UNSPSC | UNSPSC 21.0: 32151600 |
Description other products