PHOENIX CONTACTNot available

AXL F DI32/1 1F - Digital module

AxiolineF, Digital input module, Digital inputs: 32, 24 VDC, connection technology: 1-conductor, transmission speed in the local bus:100 Mbps, degree of protection: IP20, including bus base module and AxiolineF connectors
Product Code: 2688035
Partner cod.: 2688035
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3f783436b27c3846a361ee861b282789/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a THÂ35-7.5 DIN rail is used (in accordance with ENÂ60715).
InterfacesAxiolineÂFÂlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 4 Byte
Output address area: 0 Byte
Required parameter data: 3 Byte
Required configuration data: 6 Byte
Input dataDigital
Input name: Digital inputs
Description of the input: EN 61131-2 types 1 and 3
Number of inputs: 32
Connection method: Push-in connection
Connection technology: 1-conductor
Input voltage range "0" signal: -3 VÂDC ... 5 VÂDC
Input voltage range "1" signal: 11 VÂDC ... 30 VÂDC
Nominal input voltage UIN: 24 VÂDC
Nominal input current at UIN: 2.4 mA
Input filter time: 3000 µs (Default)
1000 µs
< 100 µs
Protective circuit: Polarity reversal protection of the inputs; parallel diode (30ÂV, 5Âs)
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineÂF
Mounting position: any (no temperature derating)
Scope of delivery: including bus base module and AxiolineÂF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, ENÂ60664-1)
Pollution degree: 2 (IEC 60664-1, ENÂ60664-1)
Electrical propertiesMaximum power dissipation for nominal condition: 0.6 W
Potentials: AxiolineÂF local bus supply (U
Supply voltage: 5 VÂDC (via bus base module)
Current draw: max. 120 mA (up to HW 04)
max. 60 mA (from HW 05)
Power consumption: max. 600 mW (up to HW 04)
max. 300 mW (from HW 05)
Potentials: Supply for digital input modules (U
Supply voltage: 24 VÂDC
Supply voltage range: 19.2 VÂDC ... 30 VÂDC (including all tolerances, including ripple)
Current draw: max. 50 mA
Power consumption: max. 1.2 W
Protective circuit: Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; parallel diode; with external 5ÂA fuse (only for commissioning)
Electrical isolation/isolation of the voltage ranges
Test voltage: 5ÂV supply of the local bus (UBus) / 24ÂV supply (I/Os): 500 VÂAC, 50 Hz, 1 min.
Test voltage: 5ÂV supply of the local bus (UBus) / functional ground: 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24ÂV supply (I/O) / functional ground: 500 VÂAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineÂF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“AxiolineÂF: system and installation” user manual.
Applications with UL approval: only use copper conductors.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineÂF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“AxiolineÂF: system and installation” user manual.
Applications with UL approval: only use copper conductors.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00785.pdf

Approvals_01195.pdf

Approvals_01203.pdf

Approvals_01303.pdf

Approvals_01758.pdf

Approvals_01816.pdf

Approvals_01836.pdf

Approvals_01893.pdf

Approvals_01935.pdf

Data_sheet_03150.pdf

Manual_00006.pdf

Manual_00007.pdf

Manufacturer_declaration_00592.pdf

Manufacturer_declaration_01660.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Manufacturer_declaration_14398.pdf

Package_slip_00639.pdf

Package_slip_00719.pdf

Product_information_00033.pdf

Product_information_00231.pdf

Product_information_00232.pdf

Technical_drawing_37496.pdf

Various_00004.pdf