Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Type: Stand-Alone AxiolineE straight Product type: Interface converter Product family: AxiolineE Diagnostics messages: Overrange or underrange Message in the diagnostic code (in the IBIL format) Measured value invalid/no valid measured value present Message in the diagnostic code (in the IBIL format) Short circuit Message in the diagnostic code (in the IBIL format) Wire break; goes to 0mA Message in the diagnostic code (in the IBIL format) Module faulty Message in the diagnostic code (in the IBIL format) Insulation characteristics Pollution degree: 2 |
Electrical properties | Supply: IO-Link Nominal voltage for I/O supply: 24 VDC (This supply voltage is provided via the IO-Link interface of the IO-Link master.) Nominal current for every IO-Link port: max. 100 mA Current consumption: typ. 16.5 mA ±15% (at 24 V DC) max. 120 mA Protective circuit: Reverse polarity protection Short-circuit protection Overload protection |
Input data | Analog Input name: Analog input Number of inputs: 1 (current) A/D converter resolution: 12 bit Connection method: M12 connector, A-coded Connection technology: 3-conductor Current input signal: 4 mA ... 20 mA Input resistance current input: max. 500 é Data formats: IB IL, S7-compatible Filtering: None or mean-value generation over 4, 16, or 32 measured values IO-Link Number of ports: 1 Connection method: M12 connector, A-coded Connection technology: 3-conductor Specification: V1.1.1 Reverse polarity protection: yes Cycle Time: min. 2 ms Process data update: 2 ms Amount of process data: 16 bit (Input data) 16 bit (Output data) |
Signaling | Diagnostic messages Diagnostics: Overrange or underrange Message: Message in the diagnostic code (in the IBIL format) Diagnostic messagesâ Diagnostics: Measured value invalid/no valid measured value present Message: Message in the diagnostic code (in the IBIL format) Diagnostic messagesââ Diagnostics: Short circuit Message: Message in the diagnostic code (in the IBIL format) Diagnostic messagesâââ Diagnostics: Wire break; goes to 0mA Message: Message in the diagnostic code (in the IBIL format) Diagnostic messagesââââ Diagnostics: Module faulty Message: Message in the diagnostic code (in the IBIL format) |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/5ff5351b4a5945449f260aadda9c6dca/-S204x204-FJPG Width: 16.6 mm Height: 29 mm Depth: 79.5 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 60°C Degree of protection: IP65/IP67 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level) Ambient temperature (storage/transport): -25°C ... 85°C Permissible humidity (operation): 5 % ... 95 % Permissible humidity (storage/transport): 5 % ... 95 % |
Standards and regulations | Protection class: III (IEC 61140, EN61140, VDE0140-1) |
ECLASS | ECLASS-11.0: 27242601 ECLASS-12.0: 27242601 ECLASS-13.0: 27242601 |
ETIM | ETIM 9.0: EC001596 |
UNSPSC | UNSPSC 21.0: 32151600 |