AXC 3050 - Controller

Axiocontrol for the direct control of AxiolineF I/Os. With 3 Ethernet interfaces for the additional connection of distributed I/Os via PROFINET, Modbus/TCP or TCP/IP. Programming according to IEC 61131-3. Includes connector plug and marking field.
Product Code: 2700989
Partner cod.: 2700989
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesType: modular
Product type: Controller
Product family: Axiocontrol
Display
Diagnostics display: No
System propertiesProcessor: Intel® Atom™ E660 1x 1.3 GHz
Retentive data storage: 128 kByte
IEC 61131 runtime system
Program memory: 4 Mbyte
Data storage system: 8 Mbyte
Number of control tasks: 16
Axioline
Amount of process data: max. 8192 bit (per station)
max. 4096 bit (AxiolineF local bus (input))
max. 4096 bit (AxiolineF local bus (output))
Number of supported devices: max. 63 (per station)
Number of local bus devices that can be connected: max. 63 (observe current consumption)
PROFINET
Device function: PROFINET controller, PROFINET device
Specification: Version 2.3
Update rate: min. 1 ms (16 devices)
min. 2 ms (32participants)
min. 4 ms (64 devices)
min. 8 ms (32participants)
min. 16 ms (256participants)
Conformance Class: B
Number of supported devices: max. 256 (at PROFINET controller)
Device ID: 0095hex
Vendor ID: 00B0hex
Function
Diagnostics display: No
Controller redundancy: yes
Safety function: No
Functionality
Programming languages supported: Instruction list (IL)
Symbolic flowchart (SFC)
Ladder diagram (LD)
Function block diagram (FBD)
Structured text (ST)
System requirements
Engineering tool: PC Worx
Configuration tool: Config+ Version 1.01 or later
Diagnostics tool: DIAG+
Runtime system: eCLR
Application interface: OPC
Electrical propertiesMaximum power dissipation for nominal condition: max. 9.8 W
Supply
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC
Residual ripple: ± 5%
Max. current consumption: max. 976 mA (with 2A at UBus for the I/Os and UL = 24 V)
Typical current consumption: typ. 408 mA (without I/Os and UL = 24 V)
Real-time clock
Realtime clock: Yes
Potentials: Communications power U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 976 mA (with 2A at UBus for the I/Os and UL = 24 V)
Power consumption: max. 23.5 W (2.0A on UBus, UL=24V)
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Power supply unit: 2 A
Potentials
Supply voltage: 24 VDC -15% / +20% (in accordance with EN61131-2)
Input dataCounter
Input name: Counter input for 24 V signals
Number of inputs: max. 2 (via any digital inputs of the AxiolineF modules)
Input frequency: max. 100 kHz (with AXL F DI16/1 HS 1H module)
Connection dataAxiolineF connector
Connection method: Push-in connection
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
InterfacesWeb server: yes
Ethernet
Bus system: RJ45
Number of interfaces: 3
Connection method: RJ45 jack
Note on the connection method: Auto negotiation and autocrossing
Transmission speed: 10/100 Mbps
Transmission physics: Ethernet in RJ45 twisted pair
No. of channels: 3
AxiolineF local bus
Number of interfaces: 1
Connection method: Bus base module
Transmission speed: 100 Mbps
Parameterization/operation/diagnostics
Bus system: USB
Number of interfaces: 1
Connection method: Micro USB type B
Transmission speed: max. 115.2 kbps
No. of channels: 1
Service
Bus system: USB
Number of interfaces: 1
Connection method: USB type A, socket
DimensionsWidth: 100 mm
Height: 125.9 mm
Depth: 74 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C (up to 2000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Ambient temperature (assembly): -5°C ... 60°C
Permissible humidity (operation): 5 % ... 95 % (according to DINEN61131-2)
Permissible humidity (storage/transport): 5 % ... 95 % (according to DINEN61131-2)
Shock (operation): 10g (Bump endurance test according to DIN EN 60068-2-27)
Vibration (operation): 5g
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500m above mean sea level)
EMC dataConformance with EMC directives: Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Fast transients (burst)EN61000-4-4/IEC 61000-4-4 Criterion B, 2kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Conducted interferenceEN61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Noise emission test in accordance with EN61000-6-3/IEC 61000-6-3 Radio interference properties EN55022 ClassA
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
MountingMounting type: DIN rail mounting
Connection method: Push-in connection
Technical Specs
ECLASSECLASS-11.0: 27242207
ECLASS-12.0: 27242207
ECLASS-13.0: 27242207
ETIMETIM 9.0: EC000236
UNSPSCUNSPSC 21.0: 32151700
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00032.pdf

Application_note_00189.pdf

Application_note_00051.pdf

Application_note_00132.pdf

Approvals_00486.pdf

Approvals_00487.pdf

Approvals_00488.pdf

Approvals_00553.pdf

Approvals_00554.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Function_blocks_00002.pdf

Function_blocks_00006.pdf

Function_blocks_00004.pdf

Manual_00007.pdf

Manual_00006.pdf

Manual_00164.pdf

Manufacturer_declaration_00773.pdf

Manufacturer_declaration_05553.pdf

Package_slip_00624.pdf

Product_information_00033.pdf

Product_information_00277.pdf

Technical_drawing_37662.pdf