Industrial Automation
Product properties | Type: modular Product type: Controller Product family: Axiocontrol Display Diagnostics display: No |
System properties | Processor: Intel® Atom⢠E660 1x 1.3 GHz Retentive data storage: 128 kByte IEC 61131 runtime system Program memory: 4 Mbyte Data storage system: 8 Mbyte Number of control tasks: 16 Axioline Amount of process data: max. 8192 bit (per station) max. 4096 bit (AxiolineF local bus (input)) max. 4096 bit (AxiolineF local bus (output)) Number of supported devices: max. 63 (per station) Number of local bus devices that can be connected: max. 63 (observe current consumption) PROFINET Device function: PROFINET controller, PROFINET device Specification: Version 2.3 Update rate: min. 1 ms (16 devices) min. 2 ms (32participants) min. 4 ms (64 devices) min. 8 ms (32participants) min. 16 ms (256participants) Conformance Class: B Number of supported devices: max. 256 (at PROFINET controller) Device ID: 0095hex Vendor ID: 00B0hex Function Diagnostics display: No Controller redundancy: yes Safety function: No Functionality Programming languages supported: Instruction list (IL) Symbolic flowchart (SFC) Ladder diagram (LD) Function block diagram (FBD) Structured text (ST) System requirements Engineering tool: PC Worx Configuration tool: Config+ Version 1.01 or later Diagnostics tool: DIAG+ Runtime system: eCLR Application interface: OPC |
Electrical properties | Maximum power dissipation for nominal condition: max. 9.8 W Supply Supply voltage: 24 VDC Supply voltage range: 19.2 VDC ... 30 VDC Residual ripple: ± 5% Max. current consumption: max. 976 mA (with 2A at UBus for the I/Os and UL = 24 V) Typical current consumption: typ. 408 mA (without I/Os and UL = 24 V) Real-time clock Realtime clock: Yes Potentials: Communications power U Supply voltage: 24 VDC Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Current draw: max. 976 mA (with 2A at UBus for the I/Os and UL = 24 V) Power consumption: max. 23.5 W (2.0A on UBus, UL=24V) Potentials: AxiolineF local bus supply (U Supply voltage: 5 VDC (via bus base module) Power supply unit: 2 A Potentials Supply voltage: 24 VDC -15% / +20% (in accordance with EN61131-2) |
Input data | Counter Input name: Counter input for 24 V signals Number of inputs: max. 2 (via any digital inputs of the AxiolineF modules) Input frequency: max. 100 kHz (with AXL F DI16/1 HS 1H module) |
Connection data | AxiolineF connector Connection method: Push-in connection Conductor cross section, rigid: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm |
Interfaces | Web server: yes Ethernet Bus system: RJ45 Number of interfaces: 3 Connection method: RJ45 jack Note on the connection method: Auto negotiation and autocrossing Transmission speed: 10/100 Mbps Transmission physics: Ethernet in RJ45 twisted pair No. of channels: 3 AxiolineF local bus Number of interfaces: 1 Connection method: Bus base module Transmission speed: 100 Mbps Parameterization/operation/diagnostics Bus system: USB Number of interfaces: 1 Connection method: Micro USB type B Transmission speed: max. 115.2 kbps No. of channels: 1 Service Bus system: USB Number of interfaces: 1 Connection method: USB type A, socket |
Dimensions | Width: 100 mm Height: 125.9 mm Depth: 74 mm Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715). |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 60°C (up to 2000m above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Ambient temperature (assembly): -5°C ... 60°C Permissible humidity (operation): 5 % ... 95 % (according to DINEN61131-2) Permissible humidity (storage/transport): 5 % ... 95 % (according to DINEN61131-2) Shock (operation): 10g (Bump endurance test according to DIN EN 60068-2-27) Vibration (operation): 5g Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500m above mean sea level) |
EMC data | Conformance with EMC directives: Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Fast transients (burst)EN61000-4-4/IEC 61000-4-4 Criterion B, 2kV Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Conducted interferenceEN61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V Noise emission test in accordance with EN61000-6-3/IEC 61000-6-3 Radio interference properties EN55022 ClassA Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU |
Mounting | Mounting type: DIN rail mounting Connection method: Push-in connection |
ECLASS | ECLASS-11.0: 27242207 ECLASS-12.0: 27242207 ECLASS-13.0: 27242207 |
ETIM | ETIM 9.0: EC000236 |
UNSPSC | UNSPSC 21.0: 32151700 |
Description other products