Industrial Automation
IBS IL 24 BK-T/U-XC-PAC - Bus coupler


Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/20a984302842e949b5ce7beb58df3766/-S204x204-FJPG Width: 48.8 mm Height: 135 mm Depth: 71.5 mm |
Interfaces | INTERBUS Number of interfaces: 2 (Connected to functional ground with a capacitor) Connection method: Inline shield connector Transmission speed: 500 kbps Transmission physics: Copper Inline local bus Number of interfaces: 1 Connection method: Inline data jumper Transmission speed: 500 kbps |
System properties | System limits Number of supported devices: max. 63 Number of local bus devices that can be connected: max. 63 Number of devices with parameter channel: 62 Number of supported branch terminals with remote bus branch: max. 15 Module ID code (dec.): 04 ID code (hex): 04 Length code (hex): 00 Input address area: 0 Byte Output address area: 0 Byte Register length: 0 bit |
Product properties | Type: modular Product type: I/O component Product family: Inline Scope of delivery: including Inline connectors and marking fields |
Electrical properties | Maximum power dissipation for nominal condition: 30 W Protective circuit: Reverse polarity protection Potentials: Bus coupler supply U Supply voltage: 24 VÃDC (via Inline connector) Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Current draw: max. 1.25 A (with max. number of connected I/O terminal blocks) typ. 100 mA (without connected Inline I/O terminals) Potentials: Communications power (U Supply voltage: 7.5 VÃDC ñ5Ã% Potentials: Supply of analog modules (U Supply voltage: 24 VÃDC Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Potentials: Main circuit supply (U Supply voltage: 24 VÃDC Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Potentials: Segment circuit supply (U Supply voltage: 24 VÃDC Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Electrical isolation/isolation of the voltage ranges Test voltage: 5 V supply, incoming remote bus / 5 V supply outgoing remote bus: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply incoming remote bus / 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply, incoming remote bus / 24 V main supply, 24 V segment supply: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5ÃV supply incoming remote bus / functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply outgoing remote bus / I/O (UM, US): 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply outgoing remote bus / communications power (UBK, UL, UANA): 500 VÃAC, 50 Hz, 1 min. Test voltage: 5ÃV supply outgoing remote bus / functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: 7.5ÃV communications power, 24ÃV analog supply, 24ÃV bus coupler supply/functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: Communications power (UBK, UL, UANA) / I/O (UM, US): 500 VÃAC, 50 Hz, 1 min. Test voltage: 24ÃV main supply, 24ÃV segment supply/functional ground: 500 VÃAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: Inline connector Conductor connection Connection method: Spring-cage connection Conductor cross section rigid: 0.08 mm² ... 1.5 mm² Conductor cross section flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm Inline connector Connection method: Spring-cage connection Conductor cross section, rigid: 0.08 mm² ... 1.5 mm² Conductor cross section, flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 55°C -40°C ... 70°C (Extended, see section ââ¬Ã Tested successfully: use under extreme ambient conditionsâ⬠in the data sheet.) Degree of protection: IP20 Air pressure (operation): 80 kPa ... 106 kPa (up to 3000Ãm above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 10 % ... 95 % (according to DINÃENÃ61131-2) Permissible humidity (storage/transport): 10 % ... 95 % (according to DINÃENÃ61131-2) |
Standards and regulations | Protection class: III (IEC 61140, ENÃ61140, VDEÃ0140-1) |
Mounting | Mounting type: DIN rail mounting |
Description other products