Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2701516
PHOENIX CONTACTNot available

AXL E PN DI16 M12 6M - Digital module

AxiolineE, Digital input device, PROFINET, M12 fast connection technology, Digital inputs: 16, 24 VDC, connection technology: 4-conductor, Metal housing, degree of protection: IP65/IP67
Product Code: 2701516
Partner cod.: 2701516
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/a7ea2daf39eda94f8a0cd3e02b11c54f/-S204x204-FJPG
Width: 60 mm
Height: 185 mm
Depth: 38 mm
Drill hole spacing: 198.5 mm
Note on dimensions: The height is 194.5mm including the mounting panel. With fixing clips pulled out, the height is 212mm. The depth is 38mm including the mounting panel (30.5mm without the mounting panel).
Material specificationsHousing material: Zinc die-cast
InterfacesPROFINET
Number of interfaces: 2
Connection method: M12 fast connection technology
Note on the connection method: D-coded
Number of positions: 4
Transmission speed: 100 Mbps (with auto negotiation)
PROFINET​
Equipment type: PROFINET-Device
System-specific protocols: PROFINET protocols LLDP
PROFINET protocols MRP client
PROFINET protocols DCP
PROFINET protocols DCE/RPC
Protocols supported: SNMP v1
HTTP
TFTP
FTP
Input dataDigital
Input name: Digital inputs
Description of the input: EN 61131-2 types 1 and 3
Number of inputs: 16
Connection method: M12 connector, double occupancy
Connection technology: 4-conductor
Input voltage range "0" signal: 0 V ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: typ. 3 mA
Sensor current per channel: typ. 75 mA (from US)
Total sensor current: max. 1.2 A (per device)
Input filter time: < 1000 µs
Protective circuit: Overload protection, short-circuit protection of sensor supply
Product propertiesType: Stand-Alone
Product type: I/O component
Product family: AxiolineE
Electrical propertiesPotentials
Voltage supply US: 24 VDC
Power supply at US: max. 4 A
Current consumption from US: typ. 8 mA
max. 1.2 A
Supply: Module electronics and sensors
Designation: Supply of module electronics and sensors (US)
Connection method: M12 connector (T-coded)
Number of positions: 4
Supply voltage: 24 VDC
Supply voltage range: 18 VDC ... 31.2 VDC (including all tolerances, including ripple)
Current consumption: typ. 190 mA ±15% (at 24 V DC)
max. 12 A
Supply: Actuators
Designation: Supply of actuators (UA) for additional devices
Connection method: M12 connector (T-coded)
Number of positions: 4
Supply voltage: 24 VDC
Supply voltage range: 18 VDC ... 31.2 VDC (including all tolerances, including ripple)
Current consumption: typ. 3 mA ±15% (at 24 V DC)
max. 12 A
Electrical isolation/isolation of the voltage ranges
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet1): 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet2): 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/FE: 500 VAC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet1)/FE: 500 VAC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet2)/FE: 500 VAC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet1)/bus connection (Ethernet2): 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, digital inputs): 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet1): 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet2): 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/FE: 500 VAC, 50 Hz, 1 min.
Connection dataConnection method: M12 connector
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP65/IP67
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -25°C ... 85°C
Permissible humidity (operation): 5 % ... 95 %
Permissible humidity (storage/transport): 5 % ... 95 %
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: Wall mounting or DIN rail mounting; both with mounting panel.
Technical Specs
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Description
Axioline E, Digital input device, PROFINET, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-wire, Metal housing, degree of protection: IP65/IP67
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00039.pdf

Application_note_00088.pdf

Application_note_00043.pdf

Application_note_00040.pdf

Application_note_00044.pdf

Application_note_00110.pdf

Application_note_00181.pdf

Application_note_00045.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Approvals_01344.pdf

Data_sheet_03282.pdf

Manual_00152.pdf

Manufacturer_declaration_01394.pdf

Manufacturer_declaration_02324.pdf

Manufacturer_declaration_05477.pdf

Manufacturer_declaration_14583.pdf

Package_slip_00660.pdf

Package_slip_00670.pdf

Technical_drawing_37715.pdf

Various_00004.pdf