Industrial Automation
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/ce7f4782bdcb464e9a377cdf91e8c207/-S204x204-FJPG Width: 12.2 mm Height: 119.8 mm Depth: 71.5 mm |
Interfaces | Inline local bus Number of interfaces: 2 Connection method: Inline data jumper Transmission speed: 500 kbps |
System properties | Module ID code (dec.): 126 ID code (hex): 7E Length code (hex): 04 Length code (dec): 04 Process data channel: 64 bit Input address area: 8 Byte Output address area: 0 Byte Register length: 64 bit Required parameter data: 1 Byte Required configuration data: 4 Byte |
Input data | Analog Input name: Analog UTH inputs Description of the input: Differential inputs Number of inputs: 4 (Type K) Connection method: Inline connector Connection technology: 2-conductor Note regarding the connection technology: shielded A/D conversion time: typ. 120 ms A/D converter resolution: 24 bit Sensor types that can be used (TC): K Measuring principle: Sigma/Delta process Measured value representation: 16 bits (15 bits + sign bit) Process data update: < 10 ms Protective circuit: Transient protection of inputs |
Product properties | Type: modular Product type: I/O component Product family: Inline Scope of delivery: including Inline connector Diagnostics messages: Failure of the internal I/O supply I/O error message sent to the bus coupler Checksum error I/O error message sent to the bus coupler |
Electrical properties | Potentials Power consumption: typ. 1.05 W (total) max. 1.35 W (total) Potentials: Communications power (U Supply voltage: 7.5 VDC (via voltage jumper) Current draw: max. 55 mA typ. 38 mA Potentials: Supply of analog modules (U Supply voltage: 24 VDC (via voltage jumper) Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Current draw: max. 39 mA typ. 32 mA Electrical isolation/isolation of the voltage ranges Test voltage: Bus logic (local bus, communications power): 500 VAC, 50 Hz, 1 min. Test voltage: Analog I/O: 500 VAC, 50 Hz, 1 min. Test voltage: Functional ground: 500 VAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: Inline connector Conductor connection Connection method: Spring-cage connection Conductor cross section rigid: 0.08 mm² ... 1.5 mm² Conductor cross section flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm Inline connector Connection method: Spring-cage connection Conductor cross section, rigid: 0.08 mm² ... 1.5 mm² Conductor cross section, flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): 0°C ... 55°C Degree of protection: IP20 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level) Ambient temperature (storage/transport): -25°C ... 85°C Permissible humidity (operation): 10 % ... 95 % (according to DINEN61131-2) Permissible humidity (storage/transport): 10 % ... 95 % (according to DINEN61131-2) |
Standards and regulations | Protection class: III (IEC 61140, EN61140, VDE0140-1) |
Mounting | Mounting type: DIN rail mounting |
ECLASS | ECLASS-11.0: 27242601 ECLASS-12.0: 27242601 ECLASS-13.0: 27242601 |
ETIM | ETIM 9.0: EC001596 |
UNSPSC | UNSPSC 21.0: 32151600 |