Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area Utilization restrictionâ CCCex note: Use in potentially explosive areas is not permitted in China. |
Product properties | Product type: Terminal resistor MTTF: 3305 Years (SN29500 standard, temperature25°C, operating cycle21%) 1923 Years (SN29500 standard, temperature40°C, operating cycle34.25%) 911 Years (SN29500 standard, temperature40°C, operating cycle100%) Insulation characteristics Overvoltage category: II Insulation characteristicsâ Pollution degree: 2 |
Electrical properties | Electrical isolation: RS-485 // VCC Maximum power dissipation for nominal condition: 0.24 W Test voltage data interface/power supply: 1.5 kV AC (50Hz, 1min.) Supply Supply voltage range: 18 VDC ... 30 VDC (via pluggable COMBICON screw terminal block) Nominal supply voltage: 24 VDC (via pluggable COMBICON screw terminal block) Typical current consumption: 10 mA (24 V DC, no load on D-SUB) 60 mA (24 V DC, current drain at D-SUB of 150 mA) Max. current consumption: 12 mA (18 V DC, no load on D-SUB) 77 mA (18 V DC, current drain at D-SUB of 150 mA) Function Status and diagnostic indicators: LEDs: US (power supply), ACT (data activity) |
Connection data | Supply Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm² Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm² Conductor cross section, flexible [AWG]: 24 ... 12 Tightening torque: 0.6 Nm ... 0.8 Nm |
Interfaces | Signal: Modbus PROFIBUS Data: PROFIBUS acc. to IEC 61158, RS-485 2-conductor Serial transmission speed: ⤠12 Mbps Connection method: D-SUB-9, COMBICON Transmission length: ⤠1200 m (Depends on transmission speed and cable type) Termination resistor: 390 é 220 é 390 é (Can be connected) Single conductor/terminal point, rigid: 0.2 mm² ... 1.5 mm² Single-wire/terminal point, flexible: 0.2 mm² ... 1.5 mm² Max. AWG conductor cross section, flexible: 16 Min. AWG conductor cross section, flexible: 24 Single-wire/terminal point, rigid AWG max.: 16 Single-wire/terminal point, rigid AWG min.: 24 Output nominal voltage: 5 VDC |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/f787fba948051a41ada3f71b5659f395/-S204x204-FJPG Width: 22.5 mm Height: 92 mm Depth: 73 mm |
Material specifications | Material: PA 6.6-FR |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠5000 m (For restrictions, see the manufacturer's declaration for altitude operation) ⤠2000 m (Restrictions for ATEX applications) Permissible humidity (operation): 10 % ... 95 % (non-condensing) Air pressure (operation): ⤠80 kPa (When used in EX zone2) |
Approvals | CE Certificate: CE-compliant ATEX Identification: ï II 3 G Ex nA IIC T4 Gc X Note: Please follow the special installation instructions in the documentation! UL, USA/Canada Identification: 508 Listed Corrosive gas test Identification: ISA-S71.04-1985 G3 Harsh Group A |
EMC data | Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: ± 6 kV (Test Level 3) Discharge in air: ± 8 kV (Test Level 3) Indirect discharge: ± 6 kV Comments: Criterion B Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 3 GHz (Test Level 3) Field intensity: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: ± 2.2 kV (Test Level 3) Signal: ± 2.2 kV (Test Level 3) Comments: Criterion B Surge current load (surge) Standards/regulations: EN61000-4-5 Surge current load (surge)â Input: ± 0.5 kV (sym./asym.) Signal: ± 1 kV (Data line, asymmetrical) Comments: Criterion B Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V Emitted interference Standards/regulations: EN55011 Comments: Class A, industrial applications Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and regulations | Free from substances that could impair the application of coating: in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 |
Mounting | Mounting type: DIN rail mounting |
ECLASS | ECLASS-11.0: 19070403 ECLASS-12.0: 19070403 ECLASS-13.0: 19070403 |
ETIM | ETIM 9.0: EC000448 |
UNSPSC | UNSPSC 21.0: 32121600 |
Description other products