Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2702671
PHOENIX CONTACT 2702671
PHOENIX CONTACTNot available

AXL F PM EF 1F - Special function module

AxiolineF, power measurement module, input voltage: up to 400VAC (phase/neutral) or 690VAC (phase/phase), input current: up to 5AAC, transmission speed in local bus: 100Mbps, degree of protection: IP20 , including bus base module and AxiolineF connectors
Product Code: 2702671
Partner cod.: 2702671
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/80d302c6dd37e74dab200fad48709c28/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 65.5 mm
Note on dimensions: The depth applies when a THÂ35-7.5 DIN rail is used (in accordance with ENÂ60715).
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesAxiolineÂFÂlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 64 Byte
Output address area: 0 Byte
Required parameter data: 52 Byte
Required configuration data: 7 Byte
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineÂF
Mounting position: any (no temperature derating)
Operating mode: Process data mode with 32 words
Insulation characteristics
Pollution degree: 2
Electrical propertiesPotentials: AxiolineÂF local bus supply (U
Supply voltage: 5 VÂDC (via bus base module)
Current draw: max. 80 mA
typ. 73 mA
Power consumption: max. 400 mW
typ. 365 mW
Electrical isolation/isolation of the voltage ranges
Test voltage: 5ÂV supply for local bus (UBus) / peripheral range AC: 4 kV, 50 Hz, 1 min.
Test voltage: 5ÂV supply of the local bus (UBus) / functional ground: 500 VÂAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineÂF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“Axioline F: system and installation” user manual.
Only use reinforced or double-insulated conductors with a conductor cross section of 1.5Âmm².
AxiolineÂF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“Axioline F: system and installation” user manual.
Only use reinforced or double-insulated conductors with a conductor cross section of 1.5Âmm².
Conductor cross section, rigid: 1.5 mm²
Conductor cross section, flexible: 1.5 mm²
Conductor cross section AWG: 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (Up to 3000Âm above sea level, from HWÂ01)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: II
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01227.pdf

Approvals_01228.pdf

Approvals_01759.pdf

Data_sheet_03369.pdf

Manual_00006.pdf

Manual_00007.pdf

Manual_00188.pdf

Manufacturer_declaration_01058.pdf

Manufacturer_declaration_01833.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Package_slip_00751.pdf

Product_information_00033.pdf

Product_information_00327.pdf

Technical_drawing_37863.pdf