PHOENIX CONTACT 2702877
PHOENIX CONTACT 2702877
PHOENIX CONTACTNot available

RAD-900-DAIO6 - Wireless module

Radioline - 900MHz wireless transceiver with six integrated I/O channels, NEMA 4X enclosure, N (female) antenna connection, omnidirectional antenna, point-to-point, star, and mesh networks up to 250stations, range of up to 32km (line of sight), for use in North America
Product Code: 2702877
Partner cod.: 2702877
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesTrade restriction
CE note: The products are offered exclusively for export outside the EU and the European Economic Area.
Product propertiesProduct type: Wireless module
Insulation characteristics
Overvoltage category: II
Degree of pollution: 2
Electrical propertiesElectrical isolation: 300 V (Rated insulation voltage (in each case between the analog inputs/analog outputs/AC supply, reinforced insulation according to EN61010))
50 V (Rated insulation voltage (in each case between the analog inputs/analog outputs/DC supply, reinforced insulation according to EN61010))
300 V (Rated insulation voltage (in each case between the digital inputs and digital outputs, reinforced insulation according to EN61010))
300 V (Rated insulation voltage (in each case between the digital inputs and outputs // analog inputs and outputs, reinforced insulation in accordance with EN/IEC 61010))
Test voltage for digital I/Os: 2.5 kV AC (60 Hz, 2 s)
Test voltage for analog I/Os: 1.5 kV AC (60 Hz, 2 s)
Transient surge protection: Yes
Supply
Supply voltage: 24 VDC
Supply voltage range: 10.8 VDC ... 30.5 VDC
100 VAC ... 240 VAC
Typical current consumption: 110 mA (120VAC)
Max. current consumption: 368 mA (10.8VDC)
135 mA (30.5VDC)
116 mA (100VAC)
60 mA (240VAC)
Nominal power consumption: 3.9 W (30 dBm)
Power consumption: 7.4 W (peak; 30 dBm)
Input dataDigital
Max. current consumption: < 1 mA
Analog
Description of the input: Analog input
Number of inputs: 1
Current input signal: 0 mA ... 20 mA (can be set via DIP switches)
4 mA ... 20 mA (can be set via DIP switches)
Max. current input signal: 22 mA
Input resistance current input: < 70 Ω
Resolution: 16 bit
Precision: ≤ 0.02 % (at 25°C)
Protective circuit: Short-circuit and overload protection
Temperature coefficient, typical: typ. 0.0025 %/K (at -40°C ... +70°C)
Supply voltage: ≥ 12 VDC (For passive sensors (via terminal PWR1, +I1))
Digital​
Description of the input: Digital input
Number of inputs: 2
Min. voltage input signal: 0 V AC/DC
Max. voltage input signal: 250 V AC/DC
Switching level "0" signal: 0 V AC/DC ... 4 V AC/DC (Low-voltage input)
0 V AC/DC ... 20 V AC/DC (High-voltage input)
Switching level "1" signal: 10 V AC/DC ... 50 V AC/DC (Low-voltage input)
50 V AC/DC ... 250 V AC/DC (High-voltage input)
Input frequency: ≤ 2 Hz
Output dataDigital
Output name: Relay output
Number of outputs: 2
Contact switching type: Changeover contact
Contact material: AgSnO2
Maximum switching voltage: 250 VAC
24 VDC
Min. switching current: ≥ 10 mA
Max. switching current: 2 A
Mechanical service life: 1x 107 cycles
Electrical service life: 2x 105 cycles (At 2 A, 250 VAC, cosφ 0.4)
2x 105 cycles (At 1 A, 24 V DC, L/R = 48 ms)
Maximum switching frequency: 2 Hz
Switching capacity: 48 W (24VDC)
60 W (30VDC)
20 W (48VDC)
18 W (60VDC)
22 W (110VDC)
40 W (220 VDC)
42 W (250VDC)
Behavior of the outputs (adjustable via DIP switch): Hold / Reset
Analog
Output name: Analog output
Number of outputs: 1
Voltage output signal: 0 V ... 10 V
Max. voltage output signal: approx. 10.83 V
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
Max. current output signal: approx. 21.67 mA
Load: ≥ 10 kΩ
≤ 500 Ω
Resolution: 16 bit
Protective circuit: Transient protection of outputs
Digital​
Output name: RF link relay output
Number of outputs: 1
Contact switching type: Changeover contact
Contact material: PdRu, gold-plated
Maximum switching voltage: 30 V AC/DC
Max. switching current: 500 mA
Electrical service life: 5x 105 switching cycles with 0.5 A at 30 V DC
Analog​
Output name: RSSI voltage output
Number of outputs: 1
Voltage output signal: 0 V ... 3 V
Connection dataConnection method: Screw connection
Stripping length: 11 mm
Conductor cross section, rigid min.: 0.14 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.14 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 26
Conductor cross section AWG max.: 14
InterfacesWireless
Range: ± 32 km (The range may be considerably above or below that stated, and depends on the environment, antenna technology, and the product used)
Wireless​
Interface description: Trusted Wireless
Direction: Bi-directional
Frequency: 900 MHz
Frequency range: 902 MHz ... 928 MHz
Transmission power: max. 1 W (adjustable)
Data rate: 16 kbps (adjustable)
125 kbps (adjustable)
250 kbps (adjustable)
500 kbps (adjustable)
Minimum receiver sensitivity: -112 dBm (16 kbps)
-105 dBm (125kbps)
-102 dBm (250 kbps)
-95 dBm (500 kbps)
Antenna connection method: N (female)
Security: 128-bit data encryption
Functions
Country support: USA (FCC, Part 15.247, ID: SGV-SHR-900)
Canada (IC, RSS210, ID: 4720C-SHR900)
Wireless​​
Frequency range: 902 MHz ... 928 MHz
Frequency band: 900 MHz
Wireless standard: Trusted Wireless
SignalingStatus display: Green LED (supply voltage, PWR)
Green LED (bus communication, DAT)
Red LED (periphery error, ERR)
3x green, 1x yellow LED (LED bar graph receive quality, RSSI)
Yellow LED (digital input, DI1)
Yellow LED (digtial input, DI2)
Yellow LED (digtial output, DO1)
Yellow LED (digtial output, DO2)
DimensionsWidth: 220 mm
Height: 90 mm
Depth: 120 mm
Material specificationsColor: black
Flammability rating according to UL 94: V0
Housing material: Glass-reinforced plastic (GRP)
Environmental and real-life conditionsAmbient conditions
Degree of protection: NEMA 4
Ambient temperature (operation): -40°C ... 70°C (DC)
-40°C ... 65°C (AC)
Ambient temperature (storage/transport): -40°C ... 85°C
-40°F ... 185°F
Altitude: 2000 m
Permissible humidity (operation): 20 % ... 85 %
Permissible humidity (storage/transport): 20 % ... 85 %
Shock: in accordance with DIN EN 60068-2-27: 30g, 18 ms
Vibration (operation): in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
ApprovalsConformity/Approvals
Conformance: FCC Directive, Part 15.247
ISC Directive RSS 210
UL, USA / Canada: ANSI/ISA/CSA 22.2 61010-2-201, UL 50E Type 4
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, IIC T4
EMC dataElectromagnetic compatibility: Conformance with EMC Directive 2004/108/EC
MountingMounting type: Panel mount
Technical Specs
ECLASSECLASS-11.0: 19179090
ECLASS-12.0: 19179090
ECLASS-13.0: 19179090
ETIMETIM 8.0: EC002608
UNSPSCUNSPSC 21.0: 43222600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00010.pdf

Application_note_00011.pdf

Approvals_00172.pdf

Approvals_00173.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Manual_00195.pdf

Manufacturer_declaration_17707.pdf

Package_slip_00125.pdf

Technical_drawing_37891.pdf

Various_00005.pdf