Industrial Automation
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e9341519091e9a448874b1b5791966d8/-S204x204-FJPG Width: 30.2 mm Height: 130 mm Depth: 120 mm |
Material specifications | Color: gray Housing material: Plastic |
Mounting | Mounting type: DIN rail mounting Mounting position: vertical |
Interfaces | Basic functions: PSE/Midspan, compliant with IEEE802.3af, at Data: Power over Ethernet Serial transmission speed: 10/100/1000 Mbps Connection method: RJ45 jack No. of channels: 1 Pin assignment: 1:1 Transmission length: 100 m (including patch cables) Output nominal voltage: 54 VDC (PoE) Output power: 60 W Data: Ethernet Connection method: RJ45 CAT5e |
Product properties | Product type: Injector MTTF: 133.8 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%) |
Electrical properties | Maximum power dissipation for nominal condition: 65.52 W Supply Supply voltage range: 18 VDC ... 57 VDC (Ordinary locations) 24 VDC ... 48 VDC (Hazardous locations) Nominal supply voltage: 24 VDC 48 VDC Max. current consumption: 4.2 A 2.73 A (24VDC) 1.34 A (48VDC) Power consumption: ⤠75 W Protective circuit: Reverse polarity protection |
Connection data | Supply Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 2.5 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 2.5 mm² Conductor cross section, flexible: 0.20 mm² ... 2.50 mm² Conductor cross section, rigid: 0.20 mm² ... 2.50 mm² Conductor cross section AWG: 20 ... 12 |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (Non-certificated by UL) Ambient temperature (operation): 0°C ... 60°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠5000 m (For restrictions, see the manufacturer's declaration for altitude operation) ⤠2000 m (with UL approval) Permissible humidity (operation): 10 % ... 95 % (non-condensing) |
Approvals | CE Identification: CE-compliant UL, USA/Canada Identification: Class I, Div. 2, Groups A, B, C, D T4 Corrosive gas test Identification: ISA-S71.04-1985 G3 Harsh Group A |
EMC data | Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: ± 6 kV (Test Level 3) Discharge in air: ± 8 kV (Test Level 3) Indirect discharge: ± 6 kV Comments: Criterion B Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 3 GHz (Test Level 3) Field intensity: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: ± 2.2 kV (1minute) Signal: ± 2.2 kV (1minute) Comments: Criterion B Surge current load (surge) Standards/regulations: EN61000-4-5 Surge current load (surge)â Input: ± 0.5 kV Signal: ± 1 kV (Data line, asymmetrical) ± 2 kV (I/O cable on field side only, asymmetric) Comments: Criterion B Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V Emitted interference Standards/regulations: EN61000-6-4 Comments: Class A, industrial applications Emitted interferenceâ Standards/regulations: EN61000-6-3 Comments: Class B, domain of use: residential and small commercial |
System properties | Functionality Basic functions: PSE/Midspan, compliant with IEEE802.3af, at |
ECLASS | ECLASS-11.0: 19170112 ECLASS-12.0: 19170112 ECLASS-13.0: 19170112 |
ETIM | ETIM 9.0: EC002697 |
UNSPSC | UNSPSC 21.0: 43223300 |
Description other products