Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area Utilization restrictionâ CCCex note: Use in potentially explosive areas is not permitted in China. |
Product properties | Product type: Media converter Application: Base module MTBF: 409 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 82 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
Electrical properties | Electrical isolation: VCC // CAN Maximum power dissipation for nominal condition: 2 W Test voltage data interface/power supply: 1.5 kVrms (50Hz, 1min.) Supply Supply voltage range: 10 VDC ... 30 VDC (via pluggable COMBICON screw terminal block) Nominal supply voltage: 24 VDC (in acc. with UL) Typical current consumption: 100 mA (24VDC) Max. current consumption: 100 mA |
Output data | Switching Output name: Relay output Output description: Alarm output Number of outputs: 1 Maximum switching voltage: 60 VDC 42 VAC Limiting continuous current: 0.46 A |
Connection data | Supply Connection method: Pluggable COMBICON screw terminal block through basic module Tightening torque: 0.56 Nm ... 0.79 Nm |
Interfaces | Bit distortion, input: ± 35 % (permitted) Bit distortion, output: < 6.25 % Signal: CAN CANopen® DeviceNet⢠Data: optical FO Transmit capacity, minimum: -6.2 dBm (980/1000µm) -16.9 dBm (200/230µm) Transmission length incl. 3 dB system reserve: 100 m (F-P 980/1000 230dB/km with quick mounting connector) 800 m (F-K 200/230 10dB/km with quick mounting connector) Connection method: F-SMA Wavelength: 660 nm Minimum receiver sensitivity: -30.2 dBm Transmission medium: Polymer fiber PCF fiber Data: CAN interface, in accordance with ISO/IS11898 for DeviceNetâ¢, CAN, CANopen Serial transmission speed: ⤠800 kbps Connection method: Pluggable screw connection Transmission length: ⤠5000 m (Dependent on the data rate and the protocol used) Termination resistor: 120 é (Can be connected) Transmission medium: Copper File format/coding: Bit stuffing, NRZ |
Dimensions | Width: 22.5 mm Height: 99 mm Depth: 114.5 mm |
Material specifications | Material: PA 6.6-FR |
Cable/line | FO cable Fiber types: 200/230µm 980/1000 µm Polymer fiber PCF fiber |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -20°C ... 60°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠5000 m (For restrictions, see the manufacturer's declaration for altitude operation) Permissible humidity (operation): 30 % ... 95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant EAC Identification: EAC ATEX Identification: ï II 3 G Ex nA nC IIC T4 Gc X Note: Please follow the special installation instructions in the documentation! ATEX, FO interface Identification: ï II (2) G [Ex op is Gb] IIC ï II (2) D [Ex op is Db] IIIC Certificate: PTB06ATEX2042U Note: Please follow the special installation instructions in the documentation! UL, USA/Canada Identification: Class I, Zone 2, AEx nc IIC T5 Class I, Div. 2, Groups A, B, C, D Corrosive gas test Identification: ISA-S71.04-1985 G3 Harsh Group A |
EMC data | Noise immunity: EN 61000-6-2:2005 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Noise emission: EN 55011 Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: ± 6 kV Discharge in air: ± 8 kV Comments: Criterion B Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Field intensity: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: 2 kV (5kHz) Signal: 2 kV (5kHz) Comments: Criterion B Surge current load (surge) Input: 0.5 kV (42é) Signal: 1 kV (2 é) Comments: Criterion B Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Comments: Criterion A Voltage: 10 V Emitted interference Standards/regulations: EN55011 Comments: Class A, industrial applications Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. |
Mounting | Mounting type: DIN rail mounting |
ECLASS | ECLASS-11.0: 19170411 ECLASS-12.0: 19170411 ECLASS-13.0: 19170411 |
ETIM | ETIM 9.0: EC001467 |
UNSPSC | UNSPSC 21.0: 43201500 |