PHOENIX CONTACT 2708274
PHOENIX CONTACTNot available

PSI-MOS-PROFIB/FO 850 E - FO converters

FO converter with integrated optical diagnostics, alarm contact, for PROFIBUS up to 12 Mbps, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)
Product Code: 2708274
Partner cod.: 2708274
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Media converter
MTTF: 247 Years (SN29500 standard, temperature25°C, operating cycle21%)
200 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
130 Years (SN29500 standard, temperature40°C, operating cycle100%)
MTBF: 252 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
42 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Electrical propertiesElectrical isolation: VCC // RS-485
Maximum power dissipation for nominal condition: 2.88 W
Test voltage data interface/power supply: 1.5 kVrms (50Hz, 1min.)
Supply
Supply voltage range: 18 VDC ... 30 VDC (via pluggable COMBICON screw terminal block)
Nominal supply voltage: 24 VDC (in acc. with UL)
Typical current consumption: 120 mA (24VDC)
Max. current consumption: 130 mA
≤ 2 A (For operation in a joining station, via the DIN rail connector)
Output dataSwitching
Output name: Relay output
Output description: Alarm output
Number of outputs: 1
Maximum switching voltage: 60 VDC (Resistive Load, General Load)
30 VAC (Resistive load)
42 VAC (peak, resistive load)
Limiting continuous current: 0.46 A
Connection dataSupply
Connection method: COMBICON plug-in screw terminal block
Stripping length: 7 mm
Tightening torque: 0.56 Nm ... 0.79 Nm
InterfacesBit distortion, input: ± 35 % (permitted)
Bit distortion, output: < 6.25 %
Bit delay: < 1 bit (DIP7 = OFF, standard operation)
11 bit (DIP7 =ON, redundancy operation)
Signal: PROFIBUS
Data: optical FO
No. of channels: 1
Transmit capacity, minimum: -4.2 dBm (200/230µm)
-17.8 dBm (50/125µm)
-14.6 dBm (62,5/125 µm)
Transmission length incl. 3 dB system reserve: 2600 m (with F-G 50/125 2.5 dB/km)
3300 m (with F-G 62,5/125 3.0 dB/km)
800 m (F-K 200/230 10dB/km with quick mounting connector)
Transmission protocol: Protocol-transparent to the RS-485 interface
Connection method: B-FOC (ST®)
Wavelength: 850 nm
Minimum receiver sensitivity: -30 dBm (50/125µm)
Maximum receiver sensitivity: -3 dBm (200/230µm)
Transmission medium: PCF fiber
Multi-mode fiberglass
Data: PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control
Serial transmission speed: ≤ 12 Mbps
Connection method: D-SUB-9 female connector
Transmission length: ≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable)
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible: 14
Min. AWG conductor cross section, flexible: 24
Single-wire/terminal point, rigid AWG max.: 14
Single-wire/terminal point, rigid AWG min.: 24
Transmission medium: Copper
File format/coding: UART (11 Bit, NRZ)
Data direction switching: Automatic control
Output nominal voltage: 5 V ±0.25 (50 mA)
DimensionsWidth: 35 mm
Height: 99 mm
Depth: 106 mm
Material specificationsMaterial: PA 6.6-FR
Cable/lineFO cable
Fiber types: 50/125 µm
62.5/125 µm
Fiberglass
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
≤ 2000 m (Hazardous locations)
Permissible humidity (operation): 30 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
EAC
Identification: EAC
ATEX
Identification:  II 3 G Ex nA nC IIC T4 Gc X
Note: Please follow the special installation instructions in the documentation!
ATEX, FO interface
Identification:  II (2) G [Ex op is Gb] IIC
 II (2) D [Ex op is Db] IIIC
Certificate: PTB06ATEX2042U
Note: Please follow the special installation instructions in the documentation!
UL, USA/Canada
Identification: Class I, Zone 2, AEx nc IIC T5
Class I, Zone 2, Ex nC nL IIC T5 X
Class I, Div. 2, Groups A, B, C, D
PROFIBUS interoperability
Note: Tested by independent PNO test laboratory (PN059-485-01)
ABB certification
Identification: IndustrialIT enabled
Note: This certification is a trademark of ABB.
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
Identification: DNV GL
DNV GL data
Temperature: B
Humidity: A
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2:2005
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Noise emission: EN 55011
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 6 kV
Discharge in air: ± 8 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: ± 2 kV
Signal: ± 2 kV
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: ± 0.5 kV
Signal: ± 1 kV
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Comments: Criterion A
Voltage: 10 V
Emitted interference
Standards/regulations: EN55011
Comments: Class A, industrial applications
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsFree from substances that could impair the application of coating: in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0
Air clearances and creepage distances
Standards/regulations: DINEN60664-1
VDE0110-1
DINEN50178
EN60950
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 19170411
ECLASS-12.0: 19170411
ECLASS-13.0: 19170411
ETIMETIM 9.0: EC001467
UNSPSCUNSPSC 21.0: 43201500
Description
FO converter with integrated optical diagnostics, alarm contact, for PROFIBUS up to 12 Mbps, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00159.pdf

Application_note_00155.pdf

Application_note_00153.pdf

Application_note_00152.pdf

Application_note_00156.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00098.pdf

Approvals_00121.pdf

Approvals_00127.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01763.pdf

Data_sheet_03077.pdf

Data_sheet_03402.pdf

Manufacturer_declaration_04643.pdf

Manufacturer_declaration_05546.pdf

Manufacturer_declaration_14810.pdf

Manufacturer_declaration_17707.pdf

Package_slip_01834.pdf

Technical_drawing_38017.pdf