Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2708614
PHOENIX CONTACTNot available

PSI-MOS-PROFIB/FO 850 T-SO - FO converters

FO converter with integrated optical diagnostics, coated PCB, alarm contact, for PROFIBUS up to 12Mbps, T-coupler with two FO interfaces (BFOC), 850nm, for PCF or fiberglass cable (multimode)
Product Code: 2708614
Partner cod.: 2708614
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Media converter
MTTF: 212 Years (SN29500 standard, temperature25°C, operating cycle21%)
150 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
86 Years (SN29500 standard, temperature40°C, operating cycle100%)
MTBF: 149 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
24 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Electrical propertiesElectrical isolation: VCC // RS-485
Maximum power dissipation for nominal condition: 2.88 W
Test voltage data interface/power supply: 1.5 kVrms (50Hz, 1min.)
Supply
Supply voltage range: 18 VDC ... 30 VDC (via pluggable COMBICON screw terminal block)
Nominal supply voltage: 24 VDC (in acc. with UL)
Typical current consumption: 120 mA (24VDC)
Max. current consumption: 130 mA
≤ 2 A (For operation in a joining station, via the DIN rail connector)
Output dataSwitching
Output name: Relay output
Output description: Alarm output
Number of outputs: 1
Maximum switching voltage: 60 VDC (Resistive Load, General Load)
30 VAC (Resistive load)
42 VAC (peak, resistive load)
Limiting continuous current: 0.46 A
Connection dataSupply
Connection method: COMBICON plug-in screw terminal block
Stripping length: 7 mm
Tightening torque: 0.56 Nm ... 0.79 Nm
InterfacesBit distortion, input: ± 35 % (permitted)
Bit distortion, output: < 6.25 %
Bit delay: < 1 bit (DIP7 = OFF, standard operation)
11 bit (DIP7 =ON, redundancy operation)
Signal: PROFIBUS
Data: optical FO
No. of channels: 2
Transmit capacity, minimum: -4.2 dBm (200/230µm)
-17.8 dBm (50/125µm)
-14.6 dBm (62,5/125 µm)
Transmission length incl. 3 dB system reserve: 2600 m (with F-G 50/125 2.5 dB/km)
3300 m (with F-G 62,5/125 3.0 dB/km)
800 m (F-K 200/230 10dB/km with quick mounting connector)
Connection method: B-FOC (ST®)
Wavelength: 850 nm
Minimum receiver sensitivity: -30 dBm (50/125µm)
Maximum receiver sensitivity: -3 dBm (200/230µm)
Transmission medium: PCF fiber
Multi-mode fiberglass
Data: PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control
Serial transmission speed: ≤ 12 Mbps
Connection method: D-SUB-9 female connector
Transmission length: ≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable)
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible: 14
Min. AWG conductor cross section, flexible: 24
Single-wire/terminal point, rigid AWG max.: 14
Single-wire/terminal point, rigid AWG min.: 24
Transmission medium: Copper
File format/coding: UART (11 Bit, NRZ)
Data direction switching: Automatic control
Output nominal voltage: 5 V ±0.25 (50 mA)
DimensionsWidth: 35 mm
Height: 99 mm
Depth: 105 mm
Material specificationsMaterial: PA 6.6-FR
Cable/lineFO cable
Fiber types: 50/125 µm
62.5/125 µm
Fiberglass
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
≤ 2000 m (Hazardous locations)
Permissible humidity (operation): 30 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3 G Ex nA nC IIC T4 Gc X
Note: Please follow the special installation instructions in the documentation!
ATEX, FO interface
Identification:  II (2) G [Ex op is Gb] IIC
 II (2) D [Ex op is Db] IIIC
Certificate: PTB06ATEX2042U
Note: Please follow the special installation instructions in the documentation!
UL, USA/Canada
Identification: Class I, Zone 2, AEx nc IIC T5
Class I, Zone 2, Ex nC nL IIC T5 X
Class I, Div. 2, Groups A, B, C, D
PROFIBUS interoperability
Note: Tested by independent PNO test laboratory (PN059-485-01)
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
Identification: DNV GL
DNV GL data
Temperature: B
Humidity: A
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
Standards and regulationsAir clearances and creepage distances
Standards/regulations: DINEN60664-1
VDE0110-1
DINEN50178
EN60950
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 19170411
ECLASS-12.0: 19170411
ECLASS-13.0: 19170411
ETIMETIM 9.0: EC001467
UNSPSCUNSPSC 21.0: 43201500
Description
FO converter with integrated optical diagnostics, coated PCB, alarm contact, for PROFIBUS up to 12 Mbps, T-coupler with two FO interfaces (BFOC), 850 nm, for PCF or fiberglass cable (multimode)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00152.pdf

Application_note_00159.pdf

Application_note_00156.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00098.pdf

Approvals_00121.pdf

Approvals_00127.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01763.pdf

Data_sheet_03402.pdf

Data_sheet_03077.pdf

Manufacturer_declaration_04643.pdf

Manufacturer_declaration_05546.pdf

Manufacturer_declaration_14830.pdf

Manufacturer_declaration_17707.pdf

Package_slip_01837.pdf