PHOENIX CONTACT 2801242
PHOENIX CONTACTNot available

VAL-MS-T1/T2 48/12.5 ST - Type 1/2 surge protection plug

L-N replacement plug for VAL-MS-T1/T2 48/12.5 plug-in lighting/surge arrester.
Product Code: 2801242
Partner cod.: 2801242
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesIEC test classification: I / II
T1 / T2
EN type: T1 / T2
IEC power supply system: TN
Type: Male
Product type: Replacement plug
Product family: VALVETRAB MS
Surge protection fault message: optical
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Nominal voltage UN: 60 VAC
60 VDC
- 48 VDC (RRH)
Connection dataConnection method: pluggable
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/244085b8304de74e95f3135ca62ba23a/-S204x204-FJPG
Width: 17.5 mm
Height: 47 mm
Depth: 67.3 mm
Horizontal pitch: 1 Div.
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA 6.6/PBT
Material group: I
Housing material: PA 6.6
PBT
Protective circuitMode of protection: L-N
N-PE
(L+) - (L-)
(L+) - PE
Direction of action: L-N / L-PEN
Nominal voltage UN: 60VAC ±10% (TN)
60 VDC ±10%
-48 VDC ±10% (RRH)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 75 VAC
100 VDC
Residual current IPE: ≤ 0.6 mA
Standby power consumption PC: ≤ 45 mVA
Nominal discharge current In (8/20) µs: 12.5 kA
Maximum discharge current Imax (8/20) µs: 30 kA
Impulse discharge current (10/350)µs, charge: 6.25 As
Impulse discharge current (10/350)µs, specific energy: 39 kJ/Ω
Impulse discharge current (10/350)µs, peak value limp: 12.5 kA
Short-circuit current rating ISCCR: 25 kA
Voltage protection level Up: ≤ 0.4 kV
Residual voltage Ures: ≤ 0.4 kV (at In)
≤ 0.35 kV (at 10 kA)
≤ 0.3 kV (at 5 kA)
≤ 0.275 kV (at 4 kA)
≤ 0.25 kV (at 3kA)
TOV behavior at UT: 100 VAC (5s / withstand mode)
130 VDC (5s / withstand mode)
Response time tA: ≤ 25 ns
Max. backup fuse with branch wiring: 160 A (gG)
Additional technical data
Maximum discharge current Imax (8/20) µs: 65 kA
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
ApprovalsUL specifications
Maximum continuous operating voltage MCOV (L+) - (L-): 100 VDC
Short-circuit current rating (SCCR): 5 kA
Voltage protection rating VPR (L+) - (L-): 400 V
Nominal discharge current In (L+) - (L-): 20 kA
Mode of protection: (L+) - (L-)
Nominal voltage: 60 VDC
SPD Type: 1CA
Standards and regulationsStandards/specifications: IEC 61643-11
EN61643-11
Note: 2011
2012
MountingMounting type: on base element
Technical Specs
ECLASSECLASS-11.0: 27130890
ECLASS-13.0: 27171292
ETIMETIM 9.0: EC002496
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00200.pdf

Approvals_00342.pdf

Approvals_01767.pdf

Approvals_01785.pdf

Approvals_01874.pdf

Flyer_00002.pdf

Flyer_00001.pdf

Manufacturer_declaration_00573.pdf

Manufacturer_declaration_01991.pdf

Package_slip_00536.pdf

Technical_drawing_38517.pdf