PHOENIX CONTACT 2814731
PHOENIX CONTACTNot available

MCR-S-1-5-UI-SW-DCI-NC - Current transducers

MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0 ... 0.2 A to 0 ... 11 A, unconfigured
Product Code: 2814731
Partner cod.: 2814731
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Current transducer
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesTotal error: ≤ 1.5 % (Temperature range)
Maximum power dissipation for nominal condition: 2.2 W
Measuring category: III
Test voltage output/power supply: 500 VAC (50Hz, 60s)
Test voltage input/output: 4 kV AC (50Hz, 60s)
Test voltage input/power supply: 4 kV AC (50Hz, 60s)
Protective circuit: Surge protection; 33V suppressor diode
Step response (10-90%): 330 ms (AC)
40 ms (DC)
Temperature coefficient, typical: < 0.025 %/K
Maximum transmission error: < 0.5 % (of nominal range value under nominal conditions)
Rated insulation voltage: 300 VAC (to earth)
Supply
Supply voltage range: 20 VDC ... 30 VDC
Max. current consumption: < 50 mA (without load)
Input dataMeasurement
Number of inputs: 3
Configurable/programmable: Yes, unconfigured
Input current range: 0 A AC/DC ... 11 A AC/DC (Permitted continuous overload: 120%)
Current measuring range: 0 A AC/DC ... 1 A AC/DC
0 A AC/DC ... 5 A AC/DC
0 A AC/DC ... 10 A AC/DC
Setting range for min. input current: 0 mA AC/DC ... 200 mA AC/DC
Setting range for max. input current: 0 A AC/DC ... 11 A AC/DC
LSB: Current: 1 µA (1A)
2 µA (2A)
5 µA (5A)
10 µA (10A)
50 µA (50A)
100 µA (100A)
Overload capacity: 2 x IN (continuous)
Surge strength: 20 x IN (1 s)
Frequency measuring range: 15 Hz ... 400 Hz
Curve type: AC, DC or distorted currents
Operate threshold: 2 % (of measuring range nominal value 1/5/10 A)
Output dataSwitching: Relay
Contact switching type: 1changeover contact
Contact material: AgSnO, hard gold-plated
Maximum switching voltage: 30 VAC
36 VDC
250 VAC
Limiting continuous current: 50 mA (for gold layer, 30 V AC/ 36 V DC)
2 A (in case of a destroyed gold layer, 250 V AC)
Switching: Transistor
Continuous load current: 80 mA (Not short-circuit proof)
Output voltage range: 19 V ... 29 V (supply voltage - 1 V)
Setting range of the threshold value: 1 % ... 110 %
Setting range of the response delay: 0.1 s ... 20 s
Status display: Yellow LED
Signal: Voltage/current
Configurable/programmable: Yes, unconfigured
Voltage output signal: 0 V ... 5 V
1 V ... 5 V
0 V ... 10 V
2 V ... 10 V
-5 V ... 5 V
-10 V ... 10 V
10 V ... 0 V
10 V ... 2 V
10 V ... -10 V
5 V ... 0 V
5 V ... 1 V
5 V ... -5 V
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Load/output load voltage output: > 10 kΩ
Load/output load current output: < 500 Ω
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 14
SignalingStatus display: Green LED
DimensionsItem dimensions
Width: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide PA non-reinforced
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: < 2000 m
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UL, USA/Canada
Identification: Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Noise immunity: EN 61000-6-2
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Standards and regulationsStandards/regulations: IEC 61010-2-030
MountingMounting type: DIN rail mounting
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210123
ECLASS-12.0: 27210123
ECLASS-13.0: 27210123
ETIMETIM 9.0: EC002475
UNSPSCUNSPSC 21.0: 39121000
Description
MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0 ... 0.2 A to 0 ... 11 A, unconfigured
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01560.pdf

Approvals_01561.pdf

Data_sheet_03468.pdf

Manufacturer_declaration_01044.pdf

Manufacturer_declaration_01839.pdf

Manufacturer_declaration_05491.pdf

Manufacturer_declaration_15110.pdf

Package_slip_01586.pdf

Product_information_00033.pdf

Product_information_00375.pdf

Technical_drawing_38630.pdf