Industrial Automation
ST-REL2-KG230AC/1AU - Relay connectors


Product properties | Product type: Relay Module Operating mode: 100% operating factor Mechanical service life: approx. 2x 107 cycles |
Electrical properties | Maximum power dissipation for nominal condition: 1.15 W Test voltage (Winding/contact): 2.5 kV AC (50ÃHz, 1Ãmin., winding/contact) |
Input data | Coil side Nominal input voltage UN: 230 VÃAC Input voltage range: 184 VÃAC ... 243.8 VÃAC (20ðC) Mains frequency: 50/60 Hz Drive and function: monostable Drive (polarity): polarized Typical input current at UN: 5 mA Typical response time: 4 ms ... 10 ms (with AC) Typical release time range: 4 ms ... 10 ms (with AC) Protective circuit: Bridge rectifier; Bridge rectifier Surge protection; Varistor Operating voltage display: yes |
Output data | Switching Contact switching type: 1 N/O contact Type of switch contact: Double contact Contact material: AgPd60, hard gold-plated Maximum switching voltage: 30 VÃAC 36 VÃDC Limiting continuous current: 0.5 A Maximum inrush current: 0.2 A Interrupting rating (ohmic load) max.: 5 W (at 24 V DC) Switching: when the gold layer is destroyed Note: the following values are applicable if a gold layer is destroyed Maximum switching voltage: 125 VÃAC 150 VÃDC Limiting continuous current: 2 A Maximum inrush current: 2 A Interrupting rating (ohmic load) max.: 29 W (at 24 V DC) 29 W (at 48 V DC) 29 W (at 60 V DC) 60 VA (for 250 V AC) |
Dimensions | Width: 14.6 mm Height: 33 mm Depth: 66.5 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -20°C ... 50°C Ambient temperature (storage/transport): -20°C ... 70°C |
Standards and regulations | Standards/regulations: DINÃVDEÃ0110b, Gr. C for 250 V DC IEC 60255/DIN VDE 0435 (in relevant parts) DINÃENÃ50178/VDEÃ0160 (in relevant parts) ENÃ60730/DINÃVDEÃ0631 DINÃVDEÃ0160 (in relevant parts) |
Mounting | Mounting type: Plug-in mounting |
Description other products