PHOENIX CONTACT 2856579
PHOENIX CONTACTNot available

VAL-MS 350 VF/FM - Type 2 surge arrester

Surge voltage arrester consisting of base element with remote indicator contact and protective plug with a connection in series with a varistor and a gas-filled spark gap, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 1-channel
Product Code: 2856579
Partner cod.: 2856579
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral
Note: Usable in all low-voltage systems between L-N or L-PEN.
Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation. (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE = RA accordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a)
Product propertiesIEC test classification: II
T2
EN type: T2
IEC power supply system: TN
TT
IT
Type: DIN rail module, two-section, divisible
Product type: Surge arrester
Product family: VALVETRAB MS
Number of positions: 1
Surge protection fault message: Optical, remote indicator contact
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Indicator/remote signaling
Connection name: Remote fault indicator contact
Switching function: Changeover contact
Operating voltage: 5 VAC ... 250 VAC
30 VDC
Operating current: 5 mA AC ... 1 A AC
1 ADC
Connection dataConnection method: Screw connection
Fork-type cable lug
Screw thread: M5
Tightening torque: 3 Nm (1.5mm² ... 16mm²)
4.5 Nm (25mm²...35mm²)
Stripping length: 16 mm
Conductor cross section flexible: 1.5 mm² ... 25 mm²
1.5 mm² ... 16 mm²
Conductor cross section rigid: 1.5 mm² ... 35 mm²
Conductor cross section AWG: 15 ... 2
Remote fault indicator contact
Connection method: Plug-in/screw connection via COMBICON
Screw thread: M2
Tightening torque: 0.25 Nm
Stripping length: 7 mm
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/4f232daac991f04688a8f82ac0c5dbbd/-S204x204-FJPG
Width: 17.6 mm
Height: 96.8 mm
Depth: 65.7 mm (incl. DIN rail 7.5mm)
Horizontal pitch: 1 Div.
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA 6.6/PBT
Material group: I
Housing material: PA 6.6
PBT
Protective circuitMode of protection: L-N
L-PE
L-PEN
Direction of action: 1L-N/PE
Nominal voltage UN: 240/415VAC (TN)
240/415VAC (TT)
230VAC (IT)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 350 VAC
Rated load current IL: 80 A
Residual current IPE: ≤ 5 µA
Standby power consumption PC: ≤ 2 mVA
Nominal discharge current In (8/20) µs: 10 kA
Maximum discharge current Imax (8/20) µs: 20 kA
Short-circuit current rating ISCCR: 25 kA
Voltage protection level Up: ≤ 1.5 kV
Residual voltage Ures: ≤ 1.2 kV (at In)
≤ 1.2 kV (at 10 kA)
≤ 1.1 kV (at 5 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs: ≤ 1.5 kV
TOV behavior at UT: 415 VAC (5s / withstand mode)
440 VAC (120min / withstand mode)
Response time tA: ≤ 100 ns
Max. backup fuse with V-type through wiring: 80 A (gG)
Max. backup fuse with branch wiring: 125 A (gG)
Additional technical data
Impulse discharge current (10/350)µs, charge: 0.25 As
Impulse discharge current (10/350)µs, specific energy: 62.5 J/Ω
Impulse discharge current (10/350)µs, peak value limp: 500 A
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (only when all terminal points are used)
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
ApprovalsUL specifications
Maximum continuous operating voltage MCOV (L-N): 350 VAC
Nominal discharge current In (L-N): 10 kA
Mode of protection: L-N
Nominal voltage: 240VAC
Power distribution system: Single phase
Nominal frequency: 50/60 Hz
Measured limiting voltage MLV (L-N): 2420 V
SPD Type: 4CA
UL indicator/remote signaling
Operating voltage: 125 VAC
AC operating current: 1 A AC
UL connection data
Tightening torque: 30 lbf-in.
Conductor cross section AWG: 14 ... 2
Standards and regulationsStandards/specifications: IEC 61643-11
EN61643-11
Note: 2011
2012
MountingMounting type: DIN rail: 35 mm
Technical Specs
ECLASSECLASS-11.0: 27130805
ECLASS-13.0: 27171202
ETIMETIM 9.0: EC000941
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00200.pdf

Approvals_00313.pdf

Approvals_00314.pdf

Approvals_00980.pdf

Approvals_01668.pdf

Flyer_00002.pdf

Flyer_00001.pdf

Manufacturer_declaration_00772.pdf

Manufacturer_declaration_02300.pdf

Package_slip_00496.pdf

Technical_drawing_38853.pdf