Industrial Automation
IB IL 24 PWR IN/2-F-D-PAC - Power module
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/2182c65be3908e489150116208cdf69e/-S204x204-FJPG Width: 12.2 mm Height: 119.8 mm Depth: 71.5 mm |
Notes | Utilization restriction CCCex note: Use in potentially explosive areas is not permitted in China. |
Interfaces | Inline local bus Number of interfaces: 2 Connection method: Inline data jumper Transmission speed: 500 kbps |
System properties | Module ID code (dec.): 190 ID code (hex): BE Length code (hex): C2 Length code (dec): 194 Process data channel: 2 bit Input address area: 2 bit Output address area: 0 bit Register length: 2 bit Required parameter data: 1 Byte Required configuration data: 4 Byte |
Product properties | Type: modular Product type: I/O component Product family: Inline Number of plugs: 1 Operating mode: Process data mode with 2 bits Insulation characteristics Protection class: III (IEC 61140, EN61140, VDE0140-1) |
Electrical properties | Test section: 7.5 V supply (bus logics)/24 V supply (I/O) 500 VAC 50 Hz 1 min. 24V supply (I/O) / functional ground 500 VAC 50 Hz 1 min. 7.5V supply (bus logic)/functional ground 500 VAC 50 Hz 1 min. Protective circuit: Surge protection; Suppressor diode Reverse polarity protection; Parallel polarity protection diode Overload protection, short-circuit protection in the main and segment circuits; Fuse 5x20 with 6.3 A slow-blowFuses with other values can also be used. The maximum fuse value is 6.3A.For fuses with a value greater than 2A, only slow-blow fuses may be used. Fuse: SI 5 x 20 6, 300 AT (in scope of delivery) Supply I/O voltage: 24 VDC I/O voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Residual ripple: ± ±5% Max. current consumption: 4 A Typical current consumption: 30 mA Potentials: Communications power (U Supply voltage: 7.5 VDC (via voltage jumper) Current draw: max. 25 mA Power consumption: max. 0.19 W Potentials: Main circuit supply (U Supply voltage: 24 VDC (via Inline connector) Supply voltage range: 19.2 V ... 30 V (including all tolerances, including ripple) Current draw: typ. 4 A (nominal value) Potentials: Segment circuit supply (U Supply voltage: 24 VDC Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Current draw: typ. 4 A (nominal value) |
Connection data | Connection technology Connection name: Inline connector Conductor connection Connection method: Spring-cage connection Conductor cross section rigid: 0.08 mm² ... 1.5 mm² Conductor cross section flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm Inline connector Connection method: Spring-cage connection Conductor cross section, rigid: 0.08 mm² ... 1.5 mm² Conductor cross section, flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 55°C Ambient temperature (storage/transport): -25°C ... 85°C Permissible humidity (operation): 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 10 % ... 95 % (non-condensing) Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level) |
Mounting | Mounting type: DIN rail mounting |
ECLASS | ECLASS-11.0: 27242610 ECLASS-12.0: 27242610 ECLASS-13.0: 27242610 |
ETIM | ETIM 9.0: EC001600 |
UNSPSC | UNSPSC 21.0: 32151600 |
Description other products