Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2864406
PHOENIX CONTACTNot available

MINI MCR-SL-I-I - Signal conditioner

MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0(4) mA ... 20 mA, output signal: 0(4) mA ... 20 mA
Product Code: 2864406
Partner cod.: 2864406
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Signal conditioner
Product family: MINI Analog
No. of channels: 1
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
Electrical propertiesNo. of channels: 1
Rated insulation voltage: 50 V AC/DC
Electrical isolation: Basic insulation in accordance with EN 61010
Electrical isolation between input and output: yes
Limit frequency (3 dB): approx. 100 Hz
Maximum power dissipation for nominal condition: 250 mW
Test voltage (Input/output/supply): 1.5 kV AC (50Hz, 60s)
Protective circuit: Transient protection
Signal transmission behavior: In=Out
Step response (10-90%):  3.2 ms
Maximum temperature coefficient: < 0.01 %/K
Temperature coefficient, typical: < 0.002 %/K
Maximum transmission error: ≤ 0.1 % (of final value)
Supply
Nominal supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715)
Max. current consumption: < 20 mA
Power consumption: < 450 mW
Input dataSignal: Current
Number of inputs: 1
Configurable/programmable: no
Current input signal: 0 mA ... 20 mA
4 mA ... 20 mA
Max. current input signal: 50 mA
Input resistance current input: approx. 50 Ω
Output dataSignal
Number of outputs: 1
Configurable/programmable: no
Non-load voltage: approx. 12.5 V
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
Max. current output signal: 28 mA
Load/output load current output: < 500 Ω (at 20 mA)
Ripple: < 20 mVPP (at 500 Ω)
Connection dataConnection method: Screw connection
Stripping length: 12 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8450693c9d67004aa7841c306225c8da/-S204x204-FJPG
Width: 6.2 mm
Height: 93.1 mm
Depth: 101.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 65°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA/Canada
Identification: UL508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
Shipbuilding approval
Certificate: DNV GL TAA000020N
DNV GL data
Temperature: B
Humidity: B
Vibration: B
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Comments: Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Typical deviation from the measuring range final value: 10 %
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Typical deviation from the measuring range final value: 10 %
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Typical deviation from the measuring range final value: 10 %
Standards and regulationsElectrical isolation: Basic insulation in accordance with EN 61010
MountingMounting type: DIN rail mounting
Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail.
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210120
ECLASS-12.0: 27210120
ECLASS-13.0: 27210120
ETIMETIM 9.0: EC002653
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01225.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01943.pdf

Data_sheet_03577.pdf

Manual_00026.pdf

Manufacturer_declaration_00568.pdf

Manufacturer_declaration_02404.pdf

Manufacturer_declaration_15265.pdf

Package_slip_01652.pdf

Product_information_00033.pdf

Product_information_00462.pdf

Technical_drawing_38975.pdf