PHOENIX CONTACT 2864419
PHOENIX CONTACTNot available

MINI MCR-SL-1CP-I-I - Loop-powered isolators

MCR loop-powered isolator, 1-channel, for the electrical isolation of current signals without auxiliary power, with screw connection
Product Code: 2864419
Partner cod.: 2864419
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Passive isolators
Product family: MINI Analog
No. of channels: 1
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
Electrical propertiesNo. of channels: 1
Electrical isolation: 2-way isolation
Electrical isolation between input and output: yes
Limit frequency (3 dB): 75 Hz
Cold junction errors: ≤
Typical cold point errors: ≤
Maximum power dissipation for nominal condition: 34 mW
Signal transmission behavior: In=Out
Step response (10-90%): 5 ms (at 600 Ω load)
Maximum temperature coefficient: ≤ 0.002 %/K (of measured value / 100 Ω load)
Temperature coefficient, typical: < 0.002 %/K (of measured value / 100 Ω load)
Maximum transmission error: ≤ 0.1 % (of final value)
Additional error, load-dependent: < 0.03 % (of measured value / 100 Ω load)
Electrical isolation Input/output
Rated insulation voltage: 50 V AC/DC
Test voltage: 1.5 kV AC (50Hz, 60s)
Insulation: Basic insulation in accordance with IEC/EN61010
Supply
Supply voltage range: loop-powered, no external supply necessary
Power consumption: 34 mW
Input dataSignal: Current
Number of inputs: 1
Configurable/programmable: no
Max. voltage input signal: 18 V
Current input signal: 0 mA ... 20 mA
4 mA ... 20 mA
Max. current input signal: 40 mA
Response current: approx. 190 µA
Input voltage limitation: < 2 V (20mA)
Voltage dissipation: 1.9 V (I = 20 mA)
Output dataSignal: Current
Number of outputs: 1
Configurable/programmable: no
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
Load/output load current output: < 600 Ω (at I = 20 mA output signal)
Ripple: < 10 mVrms (at 600 Ω)
Connection dataConnection method: Screw connection
Stripping length: 12 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8450693c9d67004aa7841c306225c8da/-S204x204-FJPG
Width: 6.2 mm
Height: 93.1 mm
Depth: 101.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 65°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA/Canada
Identification: UL508 Recognized
Class I, Div. 2, Groups A, B, C, D
Shipbuilding approval
Certificate: DNV GL TAA00000BW
DNV GL data
Temperature: B
Humidity: B
Vibration: B
EMC: B
Enclosure: A
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Comments: Criterion B
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Evaluation criterion: A
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Evaluation criterion: B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Comments: Criterion B
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Evaluation criterion: A
Standards and regulationsElectrical isolation: 2-way isolation
MountingMounting type: DIN rail mounting
Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail.
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210120
ECLASS-12.0: 27210120
ECLASS-13.0: 27210120
ETIMETIM 9.0: EC002653
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00055.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Data_sheet_03578.pdf

Manual_00026.pdf

Manufacturer_declaration_00539.pdf

Manufacturer_declaration_02213.pdf

Manufacturer_declaration_15266.pdf

Package_slip_01648.pdf

Product_information_00033.pdf

Product_information_00131.pdf

Product_information_00463.pdf

Technical_drawing_38976.pdf