Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Product type: Limit value switch Product family: MINI Analog No. of channels: 1 Configuration: DIP switches Insulation characteristics Overvoltage category: II Pollution degree: 2 |
System properties | Functionality Configuration: DIP switches |
Electrical properties | No. of channels: 1 Electrical isolation: 3-way isolation Electrical isolation between input and output: yes Maximum power dissipation for nominal condition: < 405 mW Switching point accuracy: < 0.05 % Step response (0â99%): < 35 ms Maximum temperature coefficient: < 0.02 %/K Electrical isolation Input/power supply Rated insulation voltage: 50 V AC/DC Test voltage: 1.5 kV AC (50Hz, 60s) Insulation: Basic insulation in accordance with IEC/EN61010 Supply Nominal supply voltage: 24 VDC ±15% Supply voltage range: 19.2 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715) Max. current consumption: < 14 mA (at 24 V DC) Power consumption: < 330 mW (at 24 V DC) |
Input data | Signal: Voltage/current Number of inputs: 1 Voltage input signal: 0 V ... 10 V Max. voltage input signal: 30 V Current input signal: 0 mA ... 20 mA Max. current input signal: 100 mA Input resistance of voltage input: > 100 ké Input resistance current input: 50 é Specification of the switching point: With 25-speed potentiometer |
Output data | Switching: Relay Contact switching type: 1changeover contact Contact material: AgSnO2, hard gold-plated Maximum switching voltage: 250 VAC 240 VAC (UL) Limiting continuous current: 2 A Setting range of the response delay: 0 s ... 10 s (0s, 1s, 2s, 3s, 4s, 6s8s, 10s) Internal hysteresis: 0.1%, 1%, 2.5%, 5% Signal Number of outputs: 1 |
Connection data | Connection method: Screw connection Stripping length: 12 mm Screw thread: M3 Conductor cross section rigid: 0.2 mm² ... 2.5 mm² Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section AWG: 26 ... 12 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8450693c9d67004aa7841c306225c8da/-S204x204-FJPG Width: 6.2 mm Height: 93.1 mm Depth: 101.2 mm |
Material specifications | Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2 Housing material: PBT |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -20°C ... 65°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠2000 m Permissible humidity (operation): 5 % ... 95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant UKCA Certificate: UKCA-compliant UL, USA Identification: Class I, Zone 2, AEx nA nC IIC T5 UL, USA/Canada Identification: UL508 Recognized UL, Canada Identification: Class I, Zone 2, Ex nA nC IIC T5 Gc Shipbuilding approval Certificate: DNV GL TAA00002R0 DNV GL data Temperature: B Humidity: B Vibration: B EMC: A Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Noise immunity: EN 61000-6-2 Note: When being exposed to interference, there may be minimal deviations. Electromagnetic compatibility: Conformance with EMC directive Noise emission: EN 61000-6-4 Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Comments: Safety measures must be taken to prevent electrostatic discharge. Electromagnetic HF field Designation: Electromagnetic RF field Standards/regulations: EN61000-4-3 Typical deviation from the measuring range final value: 5 % Fast transients (burst) Designation: Fast transients (burst) Standards/regulations: EN61000-4-4 Typical deviation from the measuring range final value: 5 % Surge current load (surge) Standards/regulations: EN61000-4-5 Surge current load (surge)â Comments: Criterion B Conducted interference Designation: Conducted interferences Standards/regulations: EN61000-4-6 Typical deviation from the measuring range final value: 5 % |
Standards and regulations | Electrical isolation: 3-way isolation |
Mounting | Mounting type: DIN rail mounting Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail. Mounting position: any |
ECLASS | ECLASS-11.0: 27210120 ECLASS-12.0: 27210120 ECLASS-13.0: 27210120 |
ETIM | ETIM 9.0: EC002653 |
UNSPSC | UNSPSC 21.0: 39121000 |