PHOENIX CONTACT 2864480
PHOENIX CONTACTNot available

MINI MCR-SL-UI-REL - Limit value switch

MCR limit value switch, with adjustable hysteresis and delay time, with screw connection
Product Code: 2864480
Partner cod.: 2864480
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Limit value switch
Product family: MINI Analog
No. of channels: 1
Configuration: DIP switches
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
System propertiesFunctionality
Configuration: DIP switches
Electrical propertiesNo. of channels: 1
Electrical isolation: 3-way isolation
Electrical isolation between input and output: yes
Maximum power dissipation for nominal condition: < 405 mW
Switching point accuracy: < 0.05 %
Step response (0–99%): < 35 ms
Maximum temperature coefficient: < 0.02 %/K
Electrical isolation Input/power supply
Rated insulation voltage: 50 V AC/DC
Test voltage: 1.5 kV AC (50Hz, 60s)
Insulation: Basic insulation in accordance with IEC/EN61010
Supply
Nominal supply voltage: 24 VDC ±15%
Supply voltage range: 19.2 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715)
Max. current consumption: < 14 mA (at 24 V DC)
Power consumption: < 330 mW (at 24 V DC)
Input dataSignal: Voltage/current
Number of inputs: 1
Voltage input signal: 0 V ... 10 V
Max. voltage input signal: 30 V
Current input signal: 0 mA ... 20 mA
Max. current input signal: 100 mA
Input resistance of voltage input: > 100 kΩ
Input resistance current input: 50 Ω
Specification of the switching point: With 25-speed potentiometer
Output dataSwitching: Relay
Contact switching type: 1changeover contact
Contact material: AgSnO2, hard gold-plated
Maximum switching voltage: 250 VAC
240 VAC (UL)
Limiting continuous current: 2 A
Setting range of the response delay: 0 s ... 10 s (0s, 1s, 2s, 3s, 4s, 6s8s, 10s)
Internal hysteresis: 0.1%, 1%, 2.5%, 5%
Signal
Number of outputs: 1
Connection dataConnection method: Screw connection
Stripping length: 12 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8450693c9d67004aa7841c306225c8da/-S204x204-FJPG
Width: 6.2 mm
Height: 93.1 mm
Depth: 101.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 65°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA
Identification: Class I, Zone 2, AEx nA nC IIC T5
UL, USA/Canada
Identification: UL508 Recognized
UL, Canada
Identification: Class I, Zone 2, Ex nA nC IIC T5 Gc
Shipbuilding approval
Certificate: DNV GL TAA00002R0
DNV GL data
Temperature: B
Humidity: B
Vibration: B
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Comments: Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Typical deviation from the measuring range final value: 5 %
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Typical deviation from the measuring range final value: 5 %
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Comments: Criterion B
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Typical deviation from the measuring range final value: 5 %
Standards and regulationsElectrical isolation: 3-way isolation
MountingMounting type: DIN rail mounting
Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail.
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210120
ECLASS-12.0: 27210120
ECLASS-13.0: 27210120
ETIMETIM 9.0: EC002653
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01435.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Data_sheet_03581.pdf

Manual_00026.pdf

Manufacturer_declaration_00564.pdf

Manufacturer_declaration_02358.pdf

Manufacturer_declaration_15269.pdf

Package_slip_01674.pdf

Product_information_00033.pdf

Product_information_00465.pdf

Technical_drawing_38979.pdf