PHOENIX CONTACT 2866019
PHOENIX CONTACTAvailable

EMD-SL-C-OC-10 - Monitoring relay

Monitoring relay for monitoring 1-phase currents of 0…10 A AC/DC, overcurrent, supply voltage can be selected via power module, 1 changeover contact
Product Code: 2866019
Partner cod.: 2866019
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Current monitoring relay
Operating mode: 100% operating factor
Mechanical service life: approx. 2x 107 cycles
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics​
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesService life electrical: 2x 105 cycles at ohmic load, 1000 VA
Mains type: 1-phase
Rated insulation voltage: 300 V
Rated surge voltage: 4 kV
Supply
Supply voltage range: 24 VAC ... 230 VAC (see Power modules)
24 VDC (see Power modules)
Nominal power consumption: 2 VA (1.5W)
Input dataInput name: Measuring input
Measured value: DC, AC sine
Input current range: 0 mA ... 100 mA (Connection terminals: I1 and GND)
0 A ... 1 A (Connection terminals: I2 and GND)
0 A ... 10 A (Connection terminals: I3 and GND)
Overload capacity: 800 mA (at IN = 100 mA)
3 A (at IN = 1 A)
12 A (at IN = 10 A)
Input resistance current input: 470 mΩ (at IN = 100mA)
47 mΩ (at IN = 1A)
5 mΩ (at IN = 10A)
Frequency range: 48 Hz ... 63 Hz
Maximum temperature coefficient: < 0.1 %/K
Setting range for response delay: 0.2 s ... 10 s
Min. setting range: 5 % ... 95 % (from IN)
Max. setting range: 10 % ... 100 % (from IN)
Function: Overcurrent
Basic accuracy: ± 5 % (of scale end value)
Setting accuracy: ≤ 5 % (of scale end value)
Repeat accuracy: ≤ 2 %
Recovery time: 500 ms
Output dataSwitching
Contact switching type: 1 floating changeover contact
Maximum switching voltage: 250 VAC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max.: 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Output fuse: 5 A (fast-blow)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Conductor cross section rigid: 0.5 mm² ... 2.5 mm²
Conductor cross section flexible: 0.25 mm² ... 2.5 mm²
Conductor cross section AWG: 20 ... 14
DimensionsWidth: 22.5 mm
Height: 90 mm
Depth: 113 mm
Material specificationsHousing insulation material: Polyamide PA, self-extinguishing
Environmental and real-life conditionsAmbient conditions
Degree of protection (Housing): IP40 (Housing)
Degree of protection (Connection terminal blocks): IP20 (Connection terminal blocks)
Ambient temperature (operation): -25°C ... 55°C
-25°C ... 40°C (corresponds to UL508)
Ambient temperature (storage/transport): -25°C ... 70°C
Climatic class: 3K3 (in acc. with EN 60721)
Permissible humidity (operation): 15 % ... 85 %
ApprovalsCE
Certificate: CE-compliant
UL, USA/Canada
Identification: UL/C-UL Listed UL 508
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Noise immunity: EN 61000-6-2
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-3
Standards and regulationsStandards/regulations: EN50178
MountingMounting type: DIN rail mounting
Assembly instructions: on standard DIN rail NS 35 in accordance with EN 60715
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371802
ECLASS-12.0: 27371802
ECLASS-13.0: 27371802
ETIMETIM 9.0: EC001440
UNSPSCUNSPSC 21.0: 41113600
Description
Monitoring relay for monitoring 1-phase currents of 0...10 A AC/DC, overcurrent, supply voltage can be selected using power module, 1 PDT
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Data_sheet_03618.pdf

Manufacturer_declaration_01617.pdf

Manufacturer_declaration_04696.pdf

Package_slip_01007.pdf

Technical_drawing_39024.pdf